![Cerus Industrial Titan CI-001-GS2 Installation, Operation & Maintenance Manual Download Page 134](http://html1.mh-extra.com/html/cerus-industrial/titan-ci-001-gs2/titan-ci-001-gs2_installation-operation-and-maintenance-manual_2583981134.webp)
12-3
z
Overload trip
Group
Code
Parameter
Set
Range
Initial
Unit
Function
group 1
F56
[Overload trip select]
1
0 ~ 1
0
F57
[Overload trip level]
-
30 ~ 200
180
%
F58
[Overload trip time]
-
0 ~ 60
60
sec
Set F56 to 1.
Inverter output is turned off when motor is overloaded.
Inverter output is turned off when excessive current flows to the motor for F58 – [Overload
trip time].
12.3 Stall prevention
Group
Code
Parameter
Set
Range
Initial
Unit
F59
[Stall prevention select]
-
0 ~ 7
0
Function
group 1
F60
[Stall prevention level]
-
30 ~ 150
150
%
I54
[Multi-function output terminal
select]
7
12
I/O
group
I55
[Multi-function relay select]
7
0 ~18
17
During acceleration: Motor starts deceleration when current exceeding the value set in
F60 flows.
During constant run: Motor decelerates when current exceeding the value set in F60
flows.
During deceleration: Motor deceleration is stopped when inverter DC link voltage rises
above a certain voltage level.
F60: The value is set as the percent of motor rated current (H33).
I54, I55:
Inverter outputs signals through multi-function output terminal (MO) or relay
output (3ABC)
or external sequence when stall prevention function is activated. Motor stall
status still can be monitored in these codes though F59 is not selected (000).
F59: Stall prevention can be set as the table below.
During
Deceleration
During
constant
speed
During
Acceleration
Setting
Bit 2
Bit 1
Bit 0
0
-
-
-
1
-
-
9
2
-
9
-
3
-
9
9
4
9
-
-
5
9
-
9
6
9
9
-
F59
Stall prevention
7
9
9
9
Summary of Contents for Titan CI-001-GS2
Page 1: ...D GS S Compact Space Ve VFD Frequency and 5 5 5 5 8...
Page 13: ...1 4 Notes...
Page 16: ...2 3 2 2 Dimensions CI 002 GS2 4 CI 001 GS2 4...
Page 17: ...2 4 CI 003 GS2 4 CI 005 GS2 4 CI 007 GS2 4 CI 010 GS2 4 H W D W1 A A H1 W1 B B...
Page 19: ......
Page 25: ...3 6 5 5 7 5 kW 5 5 mm2 M4 3 5 mm2 M4...
Page 45: ...6 4 Notes...
Page 68: ...CHAPTER 8 CONTROL BLOCK DIAGRAM m G k G h Vk Vm w t t...
Page 71: ...8 4 Notes...
Page 119: ...10 26 Notes...
Page 141: ...12 10 Ex 2 100 2 _ _ 1 _ _ _ 76 u steady T acc T steady T dec T dec T H m U X Y...
Page 159: ...13 18 Notes...
Page 169: ...15 4...
Page 170: ...15 5 Notes...
Page 171: ......