The procedure
Chapter 19
FA4800 User Manual
Release 1.9.30
19-2
The procedure
¾
To Preolad an ODU with an IP address:
1. Using the IDU-ODU cable, connect the PoE device to the ODU, ensuring
that the cable is plugged into the PoE port marked P-LAN-OUT.
2. For connectorized ODUs, screw the RF terminators into the two antenna
ports.
3. Connect the Poe device to AC power.
4. Using a crossed LAN cable, connect the LAN-IN port of the PoE device to
the Ethernet port of the managing computer. The ODU will commence
beeping at about once per second, indicating correct operation.
5. Launch the FibeAir2000 Manager.
6. At the log on window, choose Local Connection.
Figure 19-1: Log on Window for Local Connection
7. Enter the default password,
admin
. After a few moments, the
FibeAir2000 Manager main window appears:
Note
The following procedure is generic to all Ceragon radio products. What you
see on your running FibeAir2000 Manager may differ in some details from
the screen captures used to illustrate this chapter.
Warning
A powered up ODU emits RF radiation from the antenna port (or connected
antenna). When working with a powered up connectorized ODU, always use
RF terminators.
For an ODU with an integrated antenna, ensure that the antenna is always
directed away from other people.