Other Advanced Preferences
Chapter 9
FA4800 User Manual
Release 1.9.30
9-20
Other Advanced Preferences
Setting the FibeAir2000 Manager Language
In the dialog of
Figure 9-20
, you can set the FibeAir2000 Manager inter-
face language, where other localizations are available.
Setting SNMP Parameters
Use these choices to set the SNMP monitoring interval and time-out. These
are only significant if you are using an SNMP based network management
system.
Remote Power Fail Indication
Remote power fail indication indicates to one side that the other side has
suffered a power failure. The failed site sends a final trap indication about
the power loss just before powering off.
A “Dying-Gasp” circuit identifies the power failure at a minimum interval of
20 milliseconds before the ODU or IDU powers off. During that interval a
message notifying the power failure is sent to opposite site. External alarm
output number 4 indicates power failure at the opposite site.
Troubleshooting
Use the following table to troubleshoot LED fault indications:
Table 9-7: LED fault indicators
LED
Status
Remedy
PWR
Off
Check that power is connected to the IDU
IDU
Red
Check that the IDU/ODU cable is properly wired and connected.
ODU
Red
Check that the IDU/ODU cable is properly wired and connected.
AIR I/F
Orange
Complete the installation procedure from the FibeAir2000 Manager
Red
Check the antenna alignment. Check that the radio configuration of both site A and
site B units are the same (Channel and Link ID).
SVC
Orange
Red
Off
Alarm detected at the Site B interface or Local or Remote loopback
Alarm detected at the Site A interface
Ethernet only IDU or E1/T1 not configured