Table 9-5: FibeAir2000 Manager Trap Messages
Trap Message
Severity
Remarks
Cannot bind to trap service port. Port 162 already in use by
ProcessName (pid: ProcessId)
Warning
FibeAir2000 Manager will not catch any traps from
the ODU, some other application has grabbed this
port. For further detail see
this web site
.
Device unreachable!
Error
Check connectivity to ODU
Connected to <site_name>
Information
<site_name> Site will be reset.
Information
Restore Factory Default Settings in process on Site <site_name>
Information
Factory Settings: The process was not finished due to connection
issues.
Warning
Factory setting failed due to connectivity problem
to ODU
Reset: The process was not finished due to connection issues.
Warning
Factory setting failed due to connectivity problem
to target - ODU will not be reset
Cannot Write to Monitor file. There is not enough space on the disk.
Warning
Free some space on disk on the managing
computer and retry
Windows Error: <error_ID>. Cannot Write to Monitor file.
Warning
Operating System error on the managing computer
TDM Counters were cleared for both sides
Information
Identical IP addresses at <local_site_name> and
<remote_site_name>
Warning
Set up a different IP to each site
The Product is not identified at the <local_site_name> site.
Warning
FibeAir2000 Manager is incompatible with the ODU
software version
The Product is not identified at the <remote_site_name> site.
Warning
The Product is not identified at both sites.
Warning
Product Not Identified!
Warning
The Manager identified a newer ODU release at the
<remote_site_name> site.
Warning
ODU release is newer than FibeAir2000 Manager
release.
Wizards are not available. FibeAir2000 Manager
will be used just for monitoring. Upgrade the
FibeAir2000 Manager. (You will get this message
as a pop up)
The Manager identified a newer ODU release at both sites.
Warning
The Manager identified a newer ODU release at the
<local_site_name> site.
Warning
Newer Version identified at the <local_site_name> site.
Warning
ODU release is newer than FibeAir2000 Manager
release.
Wizards are not available. FibeAir2000 Manager
will be used just for monitoring. Upgrade the
FibeAir2000 Manager.
Newer Version identified at the <remote_site_name> site.
Warning
Newer Version Identified!
Warning