Configuration with Telnet
Chapter 8
FA4800 User Manual
Release 1.9.30
8-26
you will be asked for a user name and password.
The Telnet log on user name is the password that you used to enter the
FibeAir2000 Manager (for example, the default:
admin
). The Telnet pass-
word is the corresponding Community string (default:
netman
).
Figure 8-22: Telnet session log on
A Read-Only Community string allows display only whereas a Read-Write
Community string allows display and set commands.
Supported Telnet commands are shown in
Table 8-2
. Note that some of
the commands are model-specific. For example, TDM commands will not
apply to Ethernet only and PoE based links.
Table 8-2: Telnet Commands Summary
Command
Explanation
display inventory
Displays ODU product name, Name, Location, hardware and software
revisions, uptime, MAC address, IDU product name, IDU software and
hardware revisions
display management
Displays IP, Subnet, Gateway, Traps table
display link
Displays State, Link ID, Channel BW, RSS, TSL, Frequency/ACS, DFS,
Rate/ARA, Distance
display ethernet
Displays Bridge Mode, Aging time, Port table (State, Status and action)
display tdm
Displays Clock Mode, Master Clock Mode, Current Clock, Quality, TDM
table (Line status, Error Blocks)
display ntp
Displays Time, Server and Offset
display PM <interface:AIR,LAN1,LAN2,TDM1,
TDM2,...,TDM4> <interval:current,day,month>
Shows the performance monitor tables for each interface according to
user defined monitoring intervals
set ip <ipaddr> <subnetMask> <gateway>
Set the ODU IP address, subnet mask and gateway. The user must reset
the ODU after the command completion
set trap <index:1-10> <ipaddr> <port:0-
65535>
Set a specific trap from the traps table (e.g. set trap 3 192.168.2.101
162)
set readpw <oldpasswd> <passwd>
Set the read access password (Read Community)
set writepw <oldpasswd> <passwd>
Set the read-write access password (Read-Write Community)
set trappw <oldpasswd> <passwd>
Set the trap Community string
set buzzer <mode:0=OFF,1 =ON>
Toggle the buzzer mode (0 – off, 1 – on)
set tpc<power:Value between minimal Tx power,
and maximal Tx power>
Set the ODU Tx Power. If a wrong value is entered, both min and max
values shall be displayed in the error reply