Link Lock Security Feature
Chapter 8
FA4800 User Manual
Release 1.9.30
8-12
situation where a remote ODU can be stolen and used as a “pirate”
link to steal services or information. The Link Lock feature actually
locks the local ODU to be synchronized ONLY to specific remote
ODU. It is a
site oriented
feature.
The lock can only be set from a live link. It is based on MAC
authentication and is site oriented and activated on a per ODU
basis. For example, if you lock the Site B ODU to the Site A ODU,
you must still lock the Site A ODU to the Site B ODU to ensure
complete two way locking.
Link Lock can only be removed when the link is unsynchronized. In
such a case, an alarm is raised by the FibeAir2000 Manager.
¾
To enable Link Lock:
1. Click Site A on the main tool bar.
2. Choose the Security tab. The following window is displayed:
3. Click the Link Lock check-box and then OK. You are asked to
confirm the lock:
4. Click the Yes button and you are returned to the main window of
the FibeAir2000 Manager.
Observe that a link icon is now displayed in the status bar on the bottom
right of the FibeAir2000 Manager window.