5. Minimal buffer tank temperature
In this submenu is possible to adjust buffer tank temperature.
- Factory adjusted: 20°C
- Adjustment range: 5°C - 85°C
6. DHW temperature (depend about DHW configuration)
In this submenu is possible to adjust domestic hot water temperature.
- Factory adjusted: 50°C
- Adjustment range: 40°C - 80°C
7. Differential of DHW (depend about DHW configuration)
In this submenu is possible to adjust differential for domestic hot water temperature.
- Factory adjusted: 5°C
- Adjustment range: 4°C - 40°C
8.5. GLOW
In the
Glow
menu, the glow maintenance option can be switched ON or OFF (only when selecting
"WOOD")
The Glow option keeps the glow in the upper furnace of the boiler (it shuts down the boiler fan a little
earlier than in the option without maintaining the glow) so that the next time you can continue working
with the newly added fuel, without the need for a new ignition.
Mode of operation with the Glow option: after the ignition is made for the first time and the boiler
started working, if we want to continue with the boiler, we turn on the Glow option, which can maintain
the glow for the next ignition (up to max 8 hours if using dry, hard wood). If you want to continue
heating during this glowing time (GLW operation phase), add some small wood on the glow and new
wood to the upper firebox and press the NEW LOADING button. During the grill maintenance phase
(GLW...), the boiler fan ON up every hour to ignite the glow in the upper furnace. When we want to
clean the boiler, it is advisable to turn OFF the Glow option so that the wood burns completely and as
little ash for cleaning remains in the firebox.
Temperature adjustment
Technical instructions
BioTec Plus