24VDC POWER FOR
LOW LUBE ALARM
INPUT 18 AWG
VAC FOR
LUBE PUMP MOTOR
18 AWG
110H-127 BLK
110N-128 WHT
24C-909 RED
24C-910 BRN
(+24VDC)
18 AWG
24C-909 RED
+24-803 YEL
REV
DATE
DESCRIPTION
BY
1
5-23-2016
INITIAL RELEASE
SPM
2
6-8-2016
CHANGES TO BOARD DEPICTION
SPM
16
12
A
OAK LUBE PUMP CIRCUIT
160523
OAK SET.dwg
SPM
A
B
C
D
A
B
C
D
1
2
3
4
1
2
3
4
(814) 353-9256 www.centroidcnc.com
Copyright © 2016 Centroid
Title
Size
Rev
Drawn by
Date
Filename
Sheet
of
NUMBER
2
110H-126 BLK
(110VACH)
(110VACH)
LUBE
PUMP
(L1)
ACH
(L2)
ACN
GND
ALARM NO
ALARM COM
ALARM NC
220H-227 BLK
220N-228 WHT
(24VDC COM)
(220VACH)
(220VACH)
220H-226 BLK
18 AWG
110H-127 BLK
220H-227 BLK
+24VDC CONNECTED TO THE
INPUT COMMONS WITH THE
INPUTS PULLED DOWN TO
24VDC COMMON IS STANDARD
(SEE NOTE 1)
(24VDC COM)
RESISTOR PACK (SIP) CHART
INPUT
VOLTAGE
SIP MARKING
"XXX"
VALUE
(OHMS)
5
471
470
12
102
1.0K
24
222
2.2K
NOTE 1
INPUTS REQUIRE 5, 12, OR 24VDC EXTERNAL POWER
SUPPLY. POWER SUPPLY FOR OAK BOARD CAN BE
USED. SIP RESISTOR VALUE MUST BE APPROPRIATE
FOR INPUT VOLTAGE USED FOR EACH BANK OF 4
INPUTS.
(SEE CHART)
4308R-102 LF
-XXX
SIP IDENTIFICATION - XXX VALUE
-
+
9 IN
10 IN
11 IN
12 IN
9 - 12 COM
13 IN
14 IN
15 IN
16 IN
13 - 16 COM
+24VDC
24V COM
AN OUT
AN GND
H1
H14
H2
SIP 2
OPTOS
SIP 1
OPTOS
H11
OUT 1 COM
OUT 2 COM
OUT 3 COM
OUT 4 COM
OUT 5 COM
OUT 6 COM
OUT 7 COM
OUT 8 COM
OUT 9 COM
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
OUT 7
OUT 8 N0
OUT 8 NC
OUT 9 NO
OUT 9 NC
1
2
3
4
5
6
AN GND
AN IN
SEE NOTE 1
SNUBBER
PN:1819
DRIVE
COM OUT
ENC 6
H8
1
H9
2
H10
3
H12
4
H7
ENC 5
PLC ADD CONNECTORS
GND
LC4D
REV 150209
OAK
PN:13135