6.3 C
LEARING
S
OFTWARE
F
AULTS
Clear Any Existing Faults Before Continuing:
To confirm that all faults have been cleared before continuing, press
F3 MDI
from
the main menu.
If all faults have been cleared correctly, the screen should look like Figure 6.3.1.
Troubleshooting:
If the screen shown in Figure 6.3.1 is not displayed, there is an existing fault. Check the status window
to determine the cause of the fault, fix it and try again.
If you do not know the cause of the fault, confirm that all parameters are set as required in section 4.1 and 6.1, and that all
inputs are in the correct state. Also, confirm your drive is wired correctly and configured to work with the Oak Board as set
up in the drive's technical bulletin.
CNC11 keeps a log file containing all errors and faults, along with the time and date that these errors occurred at. You can
access this log from the main menu by pressing
F7 Utility
→
F9 Logs
→
F1 Errors
.
Page 41 of 72
6.3 Clearing Software Faults
T:\_Docs working\Oak Board Manual\Oakboard install manual V2 4-10-15.odt
Figure 6.3.1
MDI mode, indicating
that all faults have been
cleared.