30
B
B
B-B
05
06
07
08
09
10
11
12
13
20
19
18
17
16
15
14
21
02
03
04
01
23
24
25
22
XXXXXXX
S
re
b
mu
n l
air
e
eir
és
ed
or
é
mu
N
re
m
mu
nn
eir
e
S
eir
es
ed
or
e
mú
N
al
oci
rt
a
m i
d
or
e
mu
N
F
I
G.
6
L
ONG
ITU
D
I
N
AL
S
E
C
TI
ON
-
CO
UPE L
ONG
ITU
D
I
N
ALE -
SC
H
N
ITT
Z
EI
C
H
N
U
NG
-
S
E
CC
I
ON
L
ONG
ITU
D
I
N
AL -
S
E
Z
I
ON
E L
ONG
ITU
D
I
N
ALE
3
ENGLISH
H
YDR
AULI
C
P
R
E
SS
HEA
D
R
HU
131
an
d
R
HU
131
-
C
*
1.
G
E
N
E
R
AL
C
HA
R
A
C
TE
R
I
S
TI
CS
Suitable for compression of electrical connectors on conductors up to 400 mm
2
(800 MCM) and
aluminium conductors up to 300 mm
2
(600 MCM).
–
Crim
p
in
g fo
rce
:
................................................................................................................. 130 kN
(14.6 sh ton)
–
Ma
x op
eratin
g p
ress
u
re
:
.............................................................................................. 700 bar (10,000 psi)
–
Oil
necessary
(displacement)
:
..................................................................................... 47 cm
3
(2.9 cu. in.)
–
Dimensi
o
ns
:
length ........................................................................................................ 245 mm (9.65 in.)
width .......................................................................................................... 89 mm (3.5 in.)
– W
ei
gh
t
:
................................................................................................................................. 3,7 kg
(8.16 lbs)
2.
APPLI
C
ATI
ON
R
A
NG
E
2.1)
The
R
HU
131
-
C
head is supplied with the
AU
13
0-
C
adaptor, which will accept semicircular
slotted dies common to
Cembre
130 kN (14.6 sh ton) tooling suitable for:
–
I
n
d
entati
o
n
on copper conductors.
–
Circ
u
lar
c
o
m
p
ressi
o
n
on copper conductors.
–
H
e
x
a
go
nal
c
o
m
p
ressi
o
n
on copper, almelec or aluminium conductors.
2.2)
With the upper adaptor
AU
13
0-
...
and lower adaptor
A
C13
0-P
, the
R
HU
131
or
R
HU
131
-
C
head
will accept:
–
P
re
-
r
ou
n
d
in
g d
ies
UP
13
0-
...
(used for converting aluminium sectoral conductor to a compact,
round
section).
–
C
o
ntainin
g d
ies
(
MV,
MVC,
MVM,
M
UA
series) and the
in
d
ent
o
rs
P
S13
0-
.../
E
(to crimp connectors on aluminium cables using the deep indent crimping system).
3.
I
NS
T
R
U
C
TI
ONS
FOR
U
S
E
(Ref. to Fig. 2 and 3)
These instructions generally refer to the
R
HU
131
-
C
head, but are also suitable for the
R
HU
131
head,
fi tted with
AU
13
0-
...
and
A
C13
0-P
adaptors (regardless of die selected).
3.1)
Settin
g
The head is equipped with a "self-lock" quick male coupler suitable for connection to a hydraulic,
pneumatic or electrical pump from the
Cembre
range.
*
The RHU131-C head is the RHU131 head fi tted with adaptor AU130-C (Ref. to Fig. 2).