Set and con-
firm the spot
welding time,
then press
without re-
leasing im-
mediately to
return to the
initial welding
screen, and
adjust the current.
Press the welding torch trigger and do not release it. The
arc is ignited and is shut off automatically when the time
is over.
7.6 AUTOMATIC SPOT WELDING (4T)
Time and current settings are the same as to 2T spot
welding. However, in this case, the operator presses and
releases the welding torch button and awaits until the
spot is done.
7.7 MANUAL PAUSE TIME WELDING (2T)
Time and current settings are the same as to 2T spot
welding. However, in this case, the operator presses and
releases the welding torch button and awaits until the
spot is done
This spot welding process alternates working and pause
times.
Widely used to obtain aesthetically pleasing welding,
without deforming the workpiece.
8 PULSE (SECTOR N)
Select and
confirm
N
sector relative
to pulse to ac-
cess PULSE
ON (chapter
8.1) or PULSE
ON-XP (chap-
ter 8.2) modes
8.1 PULSE
Select and
c o n f i r m
PULSE ON
to access
pulse pa-
r a m e t e r s
setting.
The parame-
ter activates
in red. ttiva
in rosso.
Confirm and set the selected parameter. Confirm the set
-
ting to automatically move on to the next parameter, or
turn knob B to select the desired parameter.
By means of the same method, it is possible to select:
base current, pulse frequency and percentage of peak
current vs base current (Duty Cycle).
To return to the main screen, press knob B (do not re-
lease immediately) (> 0.7 sec.)
Parameter
Min.
DEF
Max
U.M.
Ris.
Peak current
0
100
250
A.
1
Base current
5
50
Set
POINT
A
1
Frequency
0,16
0,16
2,5
KHz
Hz.
1
Duty Cycle
10
50
90
%.
1
Summary of Contents for WIN TIG DC 350 T
Page 56: ...56 C B D C F A E F D E G H AG AF H AE G...
Page 178: ...178 1341 360VA 1 6 AF AG 4 5 S R Q I L M T P O N 7 4 1 WIZ 4 1 1 5 WIZ 4 1 2 6...
Page 181: ...181 EVO LIFT EVO START EVO ST 15 EVO ST 15 EVO ST 15 7 7 1 2 193 7 2 7 3...
Page 182: ...182 7 4 0 7 7 5 2 6 7 6 4 2 7 7 2 2 8 PULSE ON 8 1 PULSE ON XP 8 2 8 1 PULSE ON...
Page 186: ...186 10 2 JOB JOB 10 1 JOB 0 7 4 2 10 1 10 3 JOB JOB 10 1 JOB 10 4 JOB JOB 10 1 JOB JOB...
Page 187: ...187 10 5 JOB JOB 10 1 JOB 0 7 10 6 JOB JOB1 EXIT 0 7 11 S 12 30 encoder 13 AWS 6010 G 0 G 5...
Page 190: ...190 Err 74 Err 75 2 19 IEC60974 4 19 1 G 19 2...
Page 191: ...191...