![Cebora ef4-ss Instruction Manual Download Page 27](http://html1.mh-extra.com/html/cebora/ef4-ss/ef4-ss_instruction-manual_2577519027.webp)
27
Fig. 14
d3
l13
l14
l15
t5
t6
t7
t8
t9
t11
t12
t10
t13
l10 l11 l12
Immediately after it shows the values preset by the weld-
ing machine manufacturer:
- date (day/month/year)
and time (hour and min
utes).
- synergic mig Process .
(led
L10
on).
- Welding wire type SG2 ø
1.0 mm.
- gas ar/18% co2.
- 2 stages start-up mode
2t.
The lower portion of the display shows (MEM, PAR, 2T/4T
and JoB) that can be selected by means of the function
keys
T6, T7, T8, T9
(see par. 8).
6.3 ALARM DISPLAY
When the machine detects a temporary alarm, displays
D1
and
D2
show a fl ashing wording related to the alarm
cause. For
example: if the wire feeder door is opened,
the wording “
OPn
”
6.4 ERROR DISPLAY
When the machine detects a serious alarm, displays
D1
and
D2
show a wording “
Err
” followed by the relevant
error code.
In this case, switch off the machine and contact technical
service (see par. 10)
.
7 MAChINE PROgRAMMINg
“Main Menu” -
T5
T6
T7
T8
T9
L10 L11 L12
L13
L14
L15
T13
T11
T10
T12
Programming is made in the
“Main Menu”
. to access,
press key
T5
and then key
T6 (MENU)
or through the
quick access menu described under paragraph 8.
in the
“ Main Menu “
, via keys
T10
and
T11
, it is possible
to select one of the list items highlighted by the yellow
band. With key
T12
enter the submenu, while with key
T13
return to the previous menu and save, at the same
time, the selection made.
A downward arrow indicates that there are additional
items not shown on the screen.
This surfi ng mode applies to all machine menus.
the available items
in the “main menu “
are:
-
“Process Parameters”
(see par. 7.1)
- “
Jobs”
(see par. 7.2)
-
“Settings”
- (see par. 7.3)
-
“Information”
(see par. 7.4)