76
REVO C
1PH from 300A to 800A
User’s manual
RS485 Serial port
The serial communication port RS485 is available on the Command Terminals.
On this port may be done a network up to 127 REVO C.
Terminal M1
Description
7
RS485 A+
8
RS485 B-
Fieldbus communication option
Other serial communication port are available as option, see Communication Manual for details.
19
20
M1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Caution:
If Bus port is not connected
or in error, all writable parameters
are set to
0
value