52
REVO C
1PH from 300A to 800A
User’s manual
10.5.8 To reset the power totals:
1) Click
Test
, if not already on the test view
2) Click
Online
3) Click
Reset Totals
4) Click
Yes
10.5.9 Setting Up and Using Data Logging
To set up data logging:
1) Click
Test
, if not already on the test view
2) Click
Online
3) Click
Load Analyzer
4) On the
Load Analyzer
view click
Data
Log
5) In the
Data Log
window ensure the
slider is set to
Log Enabled
6) Click
Set Time
7) If necessary Set the date and time and
close the date/time window
8) Set
Log Time
to the number of seconds
between records
9) Click
Connect
10) Click
Confi g
11) Click
Load Confi guration
to view the
current list of logged parameters
12) For up to ten parameters to log:
-Click
+
to add a parameter to the list
-In a row in the list either: Type a parameter’s Modbus address in the
Par
fi eld
OR
-Select the parameter from the drop down list in the
Name
fi eld
13) Click
Write Confi guration
to send the parameter list to the controller
14) Click
Close
15) Click
Disconnect
16) Close the
Data Log
window
10.5.10 To retrieve a data log fi le from the power controller:
1) Click
Test
, if not already on the test view
2) Click
Online
3) Click
Load Analyzer
4) Click
Connect
5) Select a fi le from the list
6) Click
Download
7) Select a location and click
Save
8) Wait for the fi le to download. This can take
up to ten minutes for the largest fi le
9) To delete the log fi le from the controller
memory, if desired, click
Delete File
10) Click
Disconnect
11) Close the
Data Log
window
12) Close the
Load Analyzer
window
10.6 Software General information
Here it is described the Confi gurator Software and how use it.
10.6.1 Program Window
Main Menu
Access these menus.
File menu
Exit
: close the program
Setting menu
Language
: open language Settings dialog
box
Serial Port
: open Serial Port dialog box
Option
: open General Option dialog box
? (Help) menu
Message Log
: open a serial
communication message view
About
: displays the About dialog with the
program name and version and contact
information
Instruments selector
Select the right instrument to use:
HOME
: the default view
REVO-C
: open the Simple and Test views for a single-phase power controller
REVO-C 3PH
: access the Simple and Test views for a three-phase power controller
MSG
: opens a serial communication message view
Status Bar
Indicates information such as time and date, communications port and baud rate.