REVO C
3PH from 30A to 40A
User’s manual
43
Parameter Name
Description
Range
Unit
Modbus
Address
Par.
Type
Analog In 1
Indicates the percent of full scale measured
by analog input 1
0 to 100.0
%
138
Read
Only
Analog In 2
Indicates the percent of full scale measured
by analog input 2
0 to 100.0
%
137
Read
Only
Version
Indicates the software version number (x.xx.x) 0 to 65535
48
Read
Only
Release
Indicates the software release date year and
week (yyww)
0 to 65535
49
Read
Only
Unit Type
Indicates the type of power controller
36
Read
Only
Option
Description
Value
1 Leg
Single Phase
7
2 Leg
Two Leg, three phase
8
3 Leg
Three Leg, three phase
9
3 Leg PA
Three Leg, three phase with phase angle capability
9999
Parameter Name
Description
Range
Unit
Modbus
Address
Par.
Type
Max Voltage
Indicates the maximum voltage rating of the
power controller
0 to 1023
V
41
Read
Only
Max Current
Indicates the maximum current capacity of
the power controller
0 to 9999
A
62
Read
Only
Aux Voltage
Indicates the measured line voltage
0 to 1023
V
43
Read
Only
Serial Number
Indicates the serial number of the power
controller
0 to 9999
149-150
151-152
Read
Only
SCR Temperature
Indicates whether the SCR is below or above
the factory-set trip point
127
Read
Only
Option
Description
Value
Disabled
No sensor present / temperature below limit
0
Over Temp
Over temperature
130