It is 5 secs in default.
The PBX assumes call maturity from after the lapse of this time.
The FLASH function to Hold an Incoming Junction call starts working after the lapse of this time.
To change this delay time, Dial #
0000 + 03 TT # Where, TT= 01 to 99 secs. Default value = 05 (5 secs)
.
Junction Grouping
.
Every Junction can be given a separate access code = 1,2,3,4,5,7 or 8. It cannot be 9,0 or 6. If flexible numbering is done
then the first digit of the flexible numbers cannot be used. Two set of Junction groups can be made. One group can be
accessed say by dialing 9 and the other group of Junction lines by dialing 6.
Following programming can also be used to change the Junction access code from 9 to 0. But for that, first remove the
Operator code 0. (Refer heading “
Operator Extension Setting”).
Programming procedure
Dial #
0000 + 0700 # - To make all Junction lines as normal. This is the default setting.
Dial #
0000 + 0720 # - To enable Manual LCR mode
Dial #
0000 + 0721 # - To disable Manual LCR mode
Dial #
0000 + 0730 # - PBX will allot a normal Junction line if the Special Junctions are busy.
Dial #
0000 + 0731 # - PBX will give engaged tone if the if the Special Junctions are busy.
Dial #
0000 + 0732 # - PBX will allot a Special Junction line if the Normal Junctions are busy.
Dial #
0000 + 0733 # - PBX will give engaged tone if the if the Normal Junctions are busy.
Dial #
0000 + 0740 # - To allow Incoming & Outgoing on Normal Junctions.
Dial #
0000 + 0741 # - To disallow outgoing on Normal Junctions.
Dial #
0000 + 0750 # - To allow Incoming & Outgoing on Special Junctions.
Dial #
0000 + 0751 # - To disallow outgoing on Special Junctions.
Dial #
0000 + 077 J # -
Junction “J” will be set as Special Junction. Where, J = 01 - 08 Junction number
Dial #
0000 + 0770 # - All Junction will be set as Special Junction.
Dial #
0000 + 076 J # -
Junction “J” will be in Normal mode. Where, J = 01 - 08 Junction number
Dial #
0000 + 0760 # - All Junction will be in Normal mode.
Dial #
0000 + 078K # -
Code “K” gets assigned for accessing Special Junctions in case of Manual LCR mode.
Here, K = 1,2,3,4,5,7 or 8. It cannot be 9, 0 or 6. If flexible numbering is done then the first digit of the
extension numbers cannot be used here.
.
Junction Line - FLASH
.
To send FLASH on Junction line for using Call Waiting on the Telephone Line, do the following
:
FLASH while talking on the Junction Line
Dial # 8
.
Junction Line Ring Assignment
.
Junction lines incoming ring can be set in the following 2 modes
:
Auto Attendant Mode
(PBX gives Welcome message. Refer “Auto Attendant Mode Setting” for this.)
Direct Ring Mode
(Calls land on Operator or defined extensions in Simultaneous Ring mode or Round Robin
Ring mode)
Direct Ring Mode
To set Junctions in Direct Ring mode, following are the programs
:
Dial #
0000 + 11 # (To set all Junctions in Direct Ring mode)
Dial #
0000 + 11 J # (To set selected Junctions in Direct Ring mode)
Here, J= 01 to 16 (Junction in Direct Ring Mode)
Note
:
When a junction
is set in “Direct Ring Mode”, “Auto Attendant Mode” automatically gets cancelled.
Now to define Junction landing in Simultaneous or Round Robin mode, do the following programming:
Simultaneous Ring
In this mode, incoming Junction lines ring on one or more Extensions.
Incoming ring of Junction Lines can be programmed separately for Day and Night modes as described below:
Dial #
0000 + 3 X J NN 0 #
Here, X= 0 for Day Mode and 1 for Night mode.
J= 01 to 16 (Junction Line no)
NN = Last 2 digits of the Extension No.
This programming can be repeated for one Junction Line and up to 16 Extensions.
One Junction line can be programmed to land on up to 16 Extensions.
Dial #
0000 + 3X J # (To disable Ring Assignment of one Junction) J= 01 to 16
Dial #
0000 + 3X J NN 1 # (To disable Ring Assignment of one Junction & Extension) J= 01 to 16
Default
:
All the Junction Lines land on Extension number 6001 and 6002 in Simultaneous Mode.
Example:
To assign Extension numbers 6001, 6002 & 6005 to ring for incoming calls on Junction number 2, in
Day Mode
:
Dial #
0000 + 30 + 2 # + 30 2 01 0 # + 30 2 02 0 # + 30 2 05 0 #
Round Robin Ring
In this mode, the incoming Junction
call lands on one extension. If that extension is busy or doesn’t respond within few rings then the call
shifts to another extension.
Programming
: