Map view
118
Degree of overlap
Valid values for the degree of overlap are 0, 50 or 100%.
1. Press the "Degree of overlap" button.
An input dialogue is displayed.
2. Enter the degree of overlap.
3. End the Process with "Back".
Degree of overlap
Specify with what covering a section is to be switched off if it overlaps an al-
ready worked area.
Here you can set the priority to
complete working or
the avoidance of double treatments
.
0%
The section is switched off before overlapping occurs. When working in this
mode, no missed areas result (left graphic).
50 %
The section is switched off, if half of this section is located in the region of
an already worked area (middle graphic).
100 %
The section is only switched off, if it is completely located in the region of an
already worked area (right graphic).
Summary of Contents for CCI 1200