Page 26
Recharging the Battery Pack
With a battery pack inserted and your instrument switched off plug your
supplied charging unit into the DC socket indicated below: -
The Vexo instrument will not operate while the battery pack is charging and will
immediately switch off when the charger is plugged in to the DC socket, even if
the charger is not switched on. This is normal.
If the unit switches off due to the charger plug being inserted then no settings or
recordings will be saved.
A completely discharged battery pack may need several hours to become fully
charged.
Observe the LED on the charging unit to determine the charging cycle.
When the charging unit displays a constant Green LED then charging is
complete.
For safety only use the charging unit and battery pack supplied by Castle.
LED Colour
Mode
Output
Yellow
No Battery
6.4V
Yellow
Initialisation
30mA
Orange
Fast Charge
1.3A
Green/Yellow
Top-off Charge
160mA
Green
Trickle Charge
30mA
Orange/Green
Error
30mA