6 - MAINTENANCE
WARNING
Pressurized fluid can penetrate the skin
and cause severe injuries.
The grease in the cylinder is under high
pressure. Never loosen the grease fitting
adaptor completely in order to speed up
the flow of grease.
Failure to comply could result in death or
serious injury.
W0261A
To reduce the tension:
1.
Turn the grease fitting adapter about 3 times to
loosen it and drain grease from the cylinder.
2.
When the track tension is correct, tighten the
adapter.
3.
Clean the grease adapter and fitting, then lower
the track to the ground.
4.
Repeat the same operations for the other track.
NOTICE:
if the grease fitting adaptor is damaged, grease
may leak out. Check the condition of the grease fitting
adaptor regularly and replace it if necessary.
SMIL13CEX2750AB