Wheel balancer 80-2000T. Operation Manual
p.20
20
Figure 5.6 - Measuring wheel width with a caliper
When you press
ESC
the dimensions will return to the initial values as before the
measurement start and the machine will be switched over to «New wheel» state.
After entering the parameters you can measure imbalance.
5.5 Imbalance measurement
For the imbalance measurement lower the cover or press the button
START
with the
lowered cover. Wait for the complete wheel stop. Raise the cover.
For emergency stop without completing the measurement press the button
STOP
.
During measurements mechanical effects on the machine are not allowed, it’s not allowed to lean on
the machine body, take from the machine and put on the machine accessories, tools and other objects.
ATTENTION! Before the first measurement after switching the machine, the shaft automatically
rotates on one turn with small speed.
If the automatic transition into the «New wheel» is enabled (8.1.7) in case of «zero» results
in both dimensions the machine switches from weights setting state into «New wheel» state.
5.6 Weight setting
The machine will be switched over to the weight setting state after the imbalance
measurement and wheel stop. The shaft with the wheel will automatically turn to a desired
position and weights masses will be shown on a display, Figure 5.7.
а – set the clip-on weight of 150 gr. on the left
b – set the stick-on weight of 150 gr. on the left in
"6 h" position
Figure 5.7
After the wheel stop in the desired position the mass of that weight which is to be set now
is framed and displayed by yellow colour.
To set the clip-on weight apply the weight to the rim in the position “12 h” , as it’s shown
in Figure 5.8, and fix it on the rim by slight knocking by the tool.