62-61753-21
3-19
* Displays information or setting entered in the microprocessor Configurations
+ May or may not be displayed depending on Parameter/Configuration settings
DATA
DEFINITION
*
+
PRODUCTSHIELD SETUP: This will only display when IntelliSet is installed, ProductShield setting is
ON
and ECONO, HIGH AIR and/or WINTER is/are NOT OFF.
• PRODUCTSHIELD
ECONO:
Displays ProductShield Econo setting (
OFF
,
Go To Start-Stop
OR
Go To
Continuous Run
•• ECONO MIN TEMP
Displays minimum temperature setting for activation of ProductShield Econo.
(Will only be displayed if Econo is
NOT OFF
)
•• ECONO MAX TEMP
Displays maximum temperature setting for activation of ProductShield Econo.
(Will only be displayed if Econo is
NOT OFF
)
•• ECONO DELTA-T
Displays Delta-T setting for activation of ProductShield Econo. (Will only be
displayed if Econo is
NOT OFF
)
• PRODUCTSHIELD HIGH
AIR:
Indicates if Product Shield High Air is
ON
or
OFF
•• HIGH AIR MIN TEMP
Displays minimum ambient temperature setting for activation of ProductShield
High Air (Will only be displayed if High Air is
ON
)
•• HIGH AIR MAX TEMP
Displays maximum temperature setting for activation of ProductShield High Air
(Will only be displayed if High Air is
ON
)
•• HIGH AIR DELTA-T
Displays Delta-T setting for activation of ProductShield High Air (Will only be
displayed if High Air is
ON
)
• PRODUCTSHIELD:
WINTER - xx°
Indicates the ambient temperature below which ProductShield Winter will be
active (Will only be displayed if WINTER is
NOT OFF
)
*
+
RANGE 1 LOCK
This is only displayed when Range Lock 1 is configured ON.
Displays Range Lock 1 setting:
OFF = Temperature Range 1 Lock is turned off.
CONTINUOUS = When the set point is set between Range 1 Minimum & Max-
imum Temperatures, the unit is set to operate only in Continuous.
START-STOP - When the set point is set between Range 1 Minimum & Maxi-
mum Temperatures, the unit is set to operate only in Start-Stop.
*
+
•RANGE 1 MINIMUM TEMP Displays minimum temperature setting for Range 1. (Will only be displayed if
Range Lock 1 is
ON
)
*
+
•RANGE 1 MAXIMUM TEMP Displays maximum temperature setting for Range 1. (Will only be displayed if
Range Lock 1 is
ON
)
*
+
RANGE 2 LOCK
This is only displayed when Range Lock 1 is configured ON.
Displays Range Lock 1 setting:
OFF = Temperature Range 2 Lock is turned off.
CONTINUOUS = When the set point is set between Range 2 Minimum & Max-
imum Temperatures, the unit is set to operate only in Continuous Run/.
START-STOP = When the set point is set between Range 2 Minimum & Max-
imum Temperatures, the unit is set to operate only in Start-Stop.
*
+
•RANGE 2 MIN. TEMP
Displays minimum temperature setting for Range 2. (Will only be displayed if
Range Lock 2 is
ON
)
*
+
•RANGE 2 MAX. TEMP
Displays maximum temperature setting for Range 2. (Will only be displayed if
Range Lock 2 is
ON
)
*
+
TEMPERATURE (REMOTE)
SENSOR 1 (or 2 or 3)
Will only display when one or more of the optional sensors are configured ON.
Displays temperate reading of remote Temperature Sensor 1 (or 2 or 3).
Summary of Contents for NDK33BN0KB
Page 2: ......
Page 3: ...OPERATION SERVICE MANUAL for VECTOR 1550 1550 CITY Trailer Refrigeration Units...
Page 4: ......
Page 14: ......
Page 22: ...62 61753 21 1 8 1 5 SAFETY DECALS 62 61343 00 Rev or 62 02139 01 Rev C 62 02143 00 Rev...
Page 24: ...62 61753 21 1 10 62 60192 00 Rev D...
Page 30: ...62 61753 21 2 6...
Page 48: ......
Page 212: ......
Page 226: ......
Page 248: ......
Page 252: ......
Page 262: ......
Page 270: ......