Alarm
NO.
Steps
ALARM / CAUSE
CORRECTIVE ACTION
76
CONDENSER MOTOR OVERHEATED (Continued)
6
Check Condenser Fan Motors
a. Disconnect power plug at motor.
Test IP circuit for continuity using ohmmeter.
If open, remove and replace motor.
If closed, then an intermittent IP circuit is suspect.
Check phase to phase and phase to ground for short
or open circuits. Refer to Section 2.11.
If motor tests good, check the DC IP circuit to micro-
processor.
7
Check Motor Operation
a. Turn the unit ON.
Check current on each phase (must be less than
shown on Section 2.11.)
Check voltage on each phase (must be within voltage
limits shown in Section 2.11.)