Operation

Water drainage

-During dehumidifying modes, remove the upper drain 

 plug from the back of the unit, install the drain connector

 (5/8" universal female mender) with 3/4" hose(locally 

 purchased). For the models without drain connector, just 

 attach the drain hose to the hole. Place the open end of 

 the hose directly over the drain area in your basement 

 floor. 

WAIT 3 MINUTES BEFORE RESUMING OPERATION

After the unit has stopped, it can not be restarted 

operation in the first 3 minutes. This is to protect the unit. 

Operation will automatically start after 3 minutes. 

POWER MANAGEMENT feature(on some models)

When the ambient temperature is lower than the setting

temperature for a period of time, the unit will be

automatically operate power management feature. The

compressor and fan motor stop. When the ambient

temperature is higher than the setting temperature, the unit

will be automatically quit the power management feature.

The compressor and (or) fan motor run.

NOTE: For unit with power management light, the light 

will illuminate under this feature.

-During heating pump mode, remove the lower drain plug

 from the back of the unit, install the drain connector(5/8" 

 universal female mender) with 3/4" hose(locally 

 purchased). For the models without drain connector, just 

 attach the drain hose to the hole. Place the open end of 

 the Hose adaptor directly over the drain area in your 

 basement floor.

 NOTE: Make sure the hose is secure so there are no 

 leaks.Direct the hose toward the drain, making sure that 

 there are no kinks that will stop the warter flowing.Place 

 the end of the hose into the drain and make sure the end 

 of the hose is down to let the water flow smoothly.(See 

 Figs with      . Do never let it up.(See Figs with     ). When 

 the continuous drain hose is not used, ensure that the 

 corresponding drain plug and knob are installed firmly to 

 prevent leakage.

X

Maintenance

-Always unplug the unit before cleaning or servicing.

-DO NOT use flammable liquids or chemicals to clean the unit. 

-DO NOT wash the unit under running water. Doing so 

 causes electrical danger.

-DO NOT operate the machine if the power supply was damaged 

 during cleaning. A damaged power cord must be replaced with a 

 new cord from the manufacturer.

Clean the Air Filter

Remove the air filter 

Upper filter

(take out)

Remove the

screw,then

take the lower

filter out.

WARNING:

MODEL A

MODEL B

MODEL A

MODEL B

MODEL A

MODEL B

15

drain hose

adaptor

Continuous 

drain hose

Remove the 

lower drain plug

drain hose

adaptor

Continuous 

drain hose

Remove the 

lower drain plug

SCALE  0.500

Remove the 

upper drain plug

Continuous 

drain hose

Remove the 

upper drain plug

Continuous 

drain hose

Uper air filter

(take out)

Lower air filter

(take out)

SCALE  0.500

SCALE  0.500

SCALE  0.500

X

drain hose

adaptor

Press the power

cord buckle into

the rear cover.

drain hose

adaptor

delivery lift <1.8m

-When the water level of the bottom tray reaches a 

 predetermined level, the unit beeps 8 times, the digital 

 display area shows "P1" . At this time the air 

 conditioning/dehumidification process will 

 immediately stop. However, the fan motor 

 will continue to operate(this is normal). 

 Carefully move the unit to a drain location, 

 remove the bottom drain plug and let the 

 water drain away. Reinstall the bottom 

 drain plug and restart the machine until 

 the "P1" symbol disappears. If the error repeats, call for  

 service. NOTE: Be sure to reinstall the bottom drain plug 

 firmly to prevent leakage before using the unit.

            CAUTION  

DO NOT operate the unit without filter because dirt 

and lint will clog it and reduce performance.

Summary of Contents for MPPD-10CRN7-QC1G1

Page 1: ...unit Make sure to save this manual for future reference This manual only describes the installation of outdoor unit When installing the indoor unit refer to the installation manual of indoor unit Ple...

Page 2: ...fety Precauti ons Cautions Warnings for using R290 R32 refrigerant only Preparations Install ation Operati on Maintenance Faults Diagnosis Design and Compliance Notes Sociabl e Remark 2 3 4 8 9 12 15...

Page 3: ...ause electrical components to short circuit DO NOT install the unit in a location that may be exposed to combustible gas as this could cause re The unit has wheels to facilitate moving Make sure not t...

Page 4: ...raffic area and where it will not be tripped over Do not operate unit with a damaged cord plug power fuse or circuit breaker Discard unit or return to an authorized service facility for examination an...

Page 5: ...ce or burn Be aware that the refrigerants may not contain an odour Appliance MPPDB 12CRN7 QB6G1 should be installed operated and stored in a room with a floor area larger than 11 m Appliance MPPDB 10C...

Page 6: ...ll possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which flammable refrigerant can possi...

Page 7: ...may not be adequate or Warnings for using R290 R32 refrigerant only 6 may need re calibration Detection equipment shall be calibrated in a refrigerant free area Ensure that the detector is not a pote...

Page 8: ...When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders e...

Page 9: ...outlet lower air filter lower air intake drain outlet 8 f ro n t rear control panel handle both sides horizontal louver blade swing automatically Caster power plug socket power cord buckle vent contro...

Page 10: ...on location should meet the following requirements Make sure that you install your unit on an even surface to minimize noise and vibration The unit must be installed near a grounded plug and the Colle...

Page 11: ...use the bolt to fasten the window sliders once they are adjusted to the proper length 3 For some models if the length of the window requires three window sliders optional use two bolts to fasten the...

Page 12: ...the exhaust system works properly All the illustrations in this manual are for explanation purpose only Your air conditioner may be slightly different The actual shape shall prevail max 120cm or 47 in...

Page 13: ...COOL mode light FAN mode light DRY mode light AUTO mode light WIRELESS light NOTE Some features ION FOLLOW ME HEAT WIRELESS etc are optional ION is not applicable for R32 R290 units Operation 12 NOTE...

Page 14: ...tion press and hold the swing button for 3 seconds to initiate the Wireless connection mode The LED DISPLAY shows AP to indicate you can set Wireless connection If connection router is successful with...

Page 15: ...the UP or DOWN button to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The system will...

Page 16: ...flow smoothly See Figs with Do never let it up See Figs with When the continuous drain hose is not used ensure that the corresponding drain plug and knob are installed firmly to prevent leakage X Mai...

Page 17: ...ter according to instructions This sound is caused by the ow of refrigerant inside the unit This is normal Maintenance Tips Clean the Unit Store the unit when not in use Be sure to clean the air lter...

Page 18: ...wall exhaust adaptor A as shown in the Installation section of this manual Unit Temperature Range NOTE To be in compliance EN 61000 3 11 the product MPPDB 12HRN7 QB6G1 shall be connected only to a su...

Page 19: ...cipality has established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at lea...

Reviews: