background image

Installation

10

Window Installation Kit

Press the exhaust hose into the window slider adaptor 

and unit adaptor, clamp automatically by elastic buckles 

of the adaptors.

Step One: Preparing the Exhaust Hose assembly

Step Two: Install the Exhaust hose assembly to the unit 

Insert unit adaptor of the Exhaust hose assembly into the 

lower groove of the air outlet of the unit while the hook of 

the adaptor is aligned with the hole seat of the air outlet 

and slide down the Exhaust hose assembly along the arrow 

direction for installation.

Unit adaptor

Window slider

adaptor

Exhaust hose

Press into

Press into

Exhaust hose 

assembly

or

Make sure the hook of the adaptor is aligned 

with the hole seat of the air outlet. 

Hook

Hole Seat

Lower groove

adaptor

Make sure the adaptor is 

inserted into the lower 

groove of the air outlet. 

Step Three: Preparing the Adjustable Window Slider

1. Depending on the size of your window, adjust the size of the 

    window slider.  

2. If the length of the window requires two window sliders, use the bolt

    to fasten the window sliders once they are adjusted to the proper

    length.

3. For some models, if the length of the window requires three window

    sliders(optional), use two bolts to fasten the window sliders once they 

    are adjusted to proper length.

Window slider A

MODEL A

MODEL A

MODEL B

MODEL B

Window slider B

Bolt

Window slider A

Window slider B

Bolt

or

or

Window slider A Window slider B Window slider C

Bolts

Window slider A Window slider B Window slider C

Bolts

Other Regions

Part

Description

1 pc
1 pc
1 pc
1 pc
1 pc

1 pc
1 pc
1 pc

1 pc

2 pc

1 pc

1 pc
1 pc

2 pc

1 set

1 set

Unit Adaptor 

Window Slider Adaptor

Window Slider A
Window Slider B

Exhaust Hose

Bolt

Foam Seal A (Adhesive)
Foam Seal B (Adhesive)
Foam Seal C (Non-adhesive)

Security Bracket and Screw

Drain Hose

Drain Hose Adaptor(only for 

heat pump mode)

Quantity

Part

Description

Quantity

Remote Controller 

and Battery

O

N

/O

FF

TE

M

P

SH

O

RT

   

CU

T

TI

M

ER

  O

N

TI

M

ER

  O

FF

M

O

DE

FA

N

SL

EE

P

SW

IN

G

LE

D

4 set

Wall Exhaust Adaptor A 

(only for wall installation) 

Wall Exhaust Adaptor B(with cap)

(only for wall installation)

Screw and anchor 

(only for wall installation)

NOTE: Items with     are optional. Slight variations in design may occur.

*

*

*

*

*

*

*

*
*

*

*

*

Power Cord Buckle

GB

Summary of Contents for MPPD-10CRN7-QC1G1

Page 1: ...unit Make sure to save this manual for future reference This manual only describes the installation of outdoor unit When installing the indoor unit refer to the installation manual of indoor unit Ple...

Page 2: ...fety Precauti ons Cautions Warnings for using R290 R32 refrigerant only Preparations Install ation Operati on Maintenance Faults Diagnosis Design and Compliance Notes Sociabl e Remark 2 3 4 8 9 12 15...

Page 3: ...ause electrical components to short circuit DO NOT install the unit in a location that may be exposed to combustible gas as this could cause re The unit has wheels to facilitate moving Make sure not t...

Page 4: ...raffic area and where it will not be tripped over Do not operate unit with a damaged cord plug power fuse or circuit breaker Discard unit or return to an authorized service facility for examination an...

Page 5: ...ce or burn Be aware that the refrigerants may not contain an odour Appliance MPPDB 12CRN7 QB6G1 should be installed operated and stored in a room with a floor area larger than 11 m Appliance MPPDB 10C...

Page 6: ...ll possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which flammable refrigerant can possi...

Page 7: ...may not be adequate or Warnings for using R290 R32 refrigerant only 6 may need re calibration Detection equipment shall be calibrated in a refrigerant free area Ensure that the detector is not a pote...

Page 8: ...When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders e...

Page 9: ...outlet lower air filter lower air intake drain outlet 8 f ro n t rear control panel handle both sides horizontal louver blade swing automatically Caster power plug socket power cord buckle vent contro...

Page 10: ...on location should meet the following requirements Make sure that you install your unit on an even surface to minimize noise and vibration The unit must be installed near a grounded plug and the Colle...

Page 11: ...use the bolt to fasten the window sliders once they are adjusted to the proper length 3 For some models if the length of the window requires three window sliders optional use two bolts to fasten the...

Page 12: ...the exhaust system works properly All the illustrations in this manual are for explanation purpose only Your air conditioner may be slightly different The actual shape shall prevail max 120cm or 47 in...

Page 13: ...COOL mode light FAN mode light DRY mode light AUTO mode light WIRELESS light NOTE Some features ION FOLLOW ME HEAT WIRELESS etc are optional ION is not applicable for R32 R290 units Operation 12 NOTE...

Page 14: ...tion press and hold the swing button for 3 seconds to initiate the Wireless connection mode The LED DISPLAY shows AP to indicate you can set Wireless connection If connection router is successful with...

Page 15: ...the UP or DOWN button to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The system will...

Page 16: ...flow smoothly See Figs with Do never let it up See Figs with When the continuous drain hose is not used ensure that the corresponding drain plug and knob are installed firmly to prevent leakage X Mai...

Page 17: ...ter according to instructions This sound is caused by the ow of refrigerant inside the unit This is normal Maintenance Tips Clean the Unit Store the unit when not in use Be sure to clean the air lter...

Page 18: ...wall exhaust adaptor A as shown in the Installation section of this manual Unit Temperature Range NOTE To be in compliance EN 61000 3 11 the product MPPDB 12HRN7 QB6G1 shall be connected only to a su...

Page 19: ...cipality has established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at lea...

Reviews: