Safety  Precautions 

 

-Installation must be performed according to the installation instructions. Improper installation 

 can cause water leakage, electrical shock, or fire.  

-Use only the included accessories and parts, and specified tools for the installation. Using 

 

non-standard parts can cause water leakage, electrical shock, fire, and injury or property damage.

-Make sure that the outlet you are using is grounded and has the appropriate voltage. The 

 power cord is equipped with a three-prong grounding plug to protect against shock.  Voltage  

 information can be found on the nameplate of the unit.

-Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you 

 intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker

 (the fuse or circuit breaker needed is determined by the maximum current of the unit. The 

 maximum current is indicated on the nameplate located on unit),  have a qualified electrician 

 install the proper receptacle. 

-Install the unit on a flat, sturdy surface. Failure to do so could result in damage or excessive 

 noise and vibration.

-

The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards.

-DO NOT modify the length of the power cord or use an extension cord to power the unit.  

-DO NOT share a single outlet with other electrical appliances. Improper power supply can 

 cause fire or electrical shock.

-DO NOT install your air conditioner in a wet room such as a bathroom or laundry room. Too 

 much exposure to water can cause electrical components to short circuit.

-

DO NOT install the unit in a location that may be exposed to combustible gas, as this could cause fire.

-The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll 

 over objects, as these could cause tipping.  

-DO NOT operate a unit that it has been dropped or damaged.

-The appliance with electric heater shall have at least 1 meter space to the combustible materials.

-Do not touch the unit with wet or damp hands or when barefoot.

-If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power 

 supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit 

 has been damaged, contact a technician or customer service for assistance.  

-In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.

-Your air conditioner should be used in such a way that it is protected from moisture. e.g. 

 condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be 

 pulled into water or any other liquid. Unplug immediately if it occurs. 

-

All wiring must be performed strictly in accordance with the wiring diagram located inside of the unit.

-The unit's circuit board(PCB) is designed with a fuse to provide overcurrent protection. The

 specifications of the fuse are printed on the circuit board, such as: T 3.15A/250V, etc.

WARNING: To prevent death or injury to the user or other people and property damage, 

the following  instructions must be followed. Incorrect operation due to ignoring of 

instructions may cause death, harm or damage. 

This symbol indicates that ignoring instructions may cause death or serious injury.

2

GB

Summary of Contents for MPPD-10CRN7-QC1G1

Page 1: ...unit Make sure to save this manual for future reference This manual only describes the installation of outdoor unit When installing the indoor unit refer to the installation manual of indoor unit Ple...

Page 2: ...fety Precauti ons Cautions Warnings for using R290 R32 refrigerant only Preparations Install ation Operati on Maintenance Faults Diagnosis Design and Compliance Notes Sociabl e Remark 2 3 4 8 9 12 15...

Page 3: ...ause electrical components to short circuit DO NOT install the unit in a location that may be exposed to combustible gas as this could cause re The unit has wheels to facilitate moving Make sure not t...

Page 4: ...raffic area and where it will not be tripped over Do not operate unit with a damaged cord plug power fuse or circuit breaker Discard unit or return to an authorized service facility for examination an...

Page 5: ...ce or burn Be aware that the refrigerants may not contain an odour Appliance MPPDB 12CRN7 QB6G1 should be installed operated and stored in a room with a floor area larger than 11 m Appliance MPPDB 10C...

Page 6: ...ll possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which flammable refrigerant can possi...

Page 7: ...may not be adequate or Warnings for using R290 R32 refrigerant only 6 may need re calibration Detection equipment shall be calibrated in a refrigerant free area Ensure that the detector is not a pote...

Page 8: ...When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders e...

Page 9: ...outlet lower air filter lower air intake drain outlet 8 f ro n t rear control panel handle both sides horizontal louver blade swing automatically Caster power plug socket power cord buckle vent contro...

Page 10: ...on location should meet the following requirements Make sure that you install your unit on an even surface to minimize noise and vibration The unit must be installed near a grounded plug and the Colle...

Page 11: ...use the bolt to fasten the window sliders once they are adjusted to the proper length 3 For some models if the length of the window requires three window sliders optional use two bolts to fasten the...

Page 12: ...the exhaust system works properly All the illustrations in this manual are for explanation purpose only Your air conditioner may be slightly different The actual shape shall prevail max 120cm or 47 in...

Page 13: ...COOL mode light FAN mode light DRY mode light AUTO mode light WIRELESS light NOTE Some features ION FOLLOW ME HEAT WIRELESS etc are optional ION is not applicable for R32 R290 units Operation 12 NOTE...

Page 14: ...tion press and hold the swing button for 3 seconds to initiate the Wireless connection mode The LED DISPLAY shows AP to indicate you can set Wireless connection If connection router is successful with...

Page 15: ...the UP or DOWN button to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The system will...

Page 16: ...flow smoothly See Figs with Do never let it up See Figs with When the continuous drain hose is not used ensure that the corresponding drain plug and knob are installed firmly to prevent leakage X Mai...

Page 17: ...ter according to instructions This sound is caused by the ow of refrigerant inside the unit This is normal Maintenance Tips Clean the Unit Store the unit when not in use Be sure to clean the air lter...

Page 18: ...wall exhaust adaptor A as shown in the Installation section of this manual Unit Temperature Range NOTE To be in compliance EN 61000 3 11 the product MPPDB 12HRN7 QB6G1 shall be connected only to a su...

Page 19: ...cipality has established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at lea...

Reviews: