Operation

Swing button

Wireless button

(optional)

Sleep(Eco) button

Fan/Ion button(Ion is optional)

Used to initiate the Auto swing feature. When 

the operation is ON, press the SWING button 

can stop the louver at the desired angle.

Used to initiate the SLEEP/ECO operation.

Timer button

Used to initiate the AUTO ON start  time and 

AUTO OFF stop time program, in conjuction 

with the + & - buttons. The timer on/off indicator

light illuminates under the timer on/off settings.

Mode button

Selects the appropriate operating mode. Each 

time you press the button, a mode is selected in 

a sequence that goes from AUTO), COOL, DRY, 

FAN and HEAT (cooling only models without). 

The mode indicator light illuminates under the 

different mode settings.

Power button

Up (+) and Down (-) buttons

Used to adjust (increasing/decreasing) 

temperature settings in 1°C/1°F (or 2 °F) 

increments in a range of 17°C/62°F to 

30°C/86°F (or 88°F) or the TIMER setting in a 

range of 0~24hrs.

NOTE: The control is capable of displaying 

 

temperature in degrees Fahrenheit or 

degrees Celsius. To convert from one to the 

other, press and hold the Up and Down 

buttons at the same time for 3 seconds.

Control the fan speed. Press to select the fan 

speed in four steps-LOW, MED, HIGH and AUTO. 

The fan speed indicator light illuminates under 

different fan settings. When select AUTO fan 

speed, all the fan indicator lights turn dark. On 

some models, when select AUTO fan speed, all 

the fan indicator lights illumiante(optional). 

NOTE: Press this button for 3 seconds to initiate 

ION feature. The ion generator is energized and 

will help to remove pollen and impurities from the 

air, and trap them in the filter. Press it for 3 

seconds again to stop the ION feature.

Used to initiate the Wireless function. For the 

first time to use Wireless function, press and 

hold the swing button for 3 seconds to initiate the 

Wireless connection mode. The LED DISPLAY 

shows 'AP' to indicate you can set Wireless 

connection. If connection(router) is successful 

within 8 minutes, the unit will exit Wireless 

connection mode automatically and the Wireless 

indicator illuminates. If connection is failure 

within 8 minutes, the unit exits Wireless 

connection mode automatically. After Wireless 

connection is successful, you can press and 

hold SWING and DOWN (-) buttons at the same 

time for 3 seconds to turn off Wireless function 

and the LED DISPLAY shows 'OF' for 3 seconds, 

press SWING and UP(+) buttons at the same 

time to turn on Wireless function and the LED 

DISPLAY shows 'ON' for 3 seconds.

NOTE: When you restart the Wireless function, 

it may take a period of time to connect to the 

network automatically.

13

Power switch on/off.

LED display

Shows the set temperature in °C or °F("°F" 

no display for some models) and the Auto-timer 

settings.  While on DRY and FAN modes, it 

shows the room temperature.

Shows Error codes and protection code:

E1-Room temperature sensor error.

E2-Evaporator temperature sensor error.

E3-Condenser temperature sensor error 

(on some models).

E4-Display panel communication error.

EC-Refrigerant leakage detection malfunction

     (on some models).

P1-Bottom tray is full--Connect the drain hose 

and drain the collected water away.If 

protection repeats,call for service.

Note: When one of the above malfunctions 

occurs, turn off the unit, and check for any 

obstructions. Restart the unit, if the 

malfunction is still present, turn off the unit 

and unplug the power cord. Contact the 

manufacturer or its service agents or a similar 

qualified person for service.

 

Exhaust hose installation

The exhaust hose and adaptor must be installed or 

removed in accordance with the usage mode. 

For COOL,HEAT(heat pump type) or  AUTO mode 

must be installed exhaust hose.

For FAN,DEHUMIDIIFY or HEAT(electrical heat

type) mode must be removed exhaust hose.

Summary of Contents for MPPD-10CRN7-QC1G1

Page 1: ...unit Make sure to save this manual for future reference This manual only describes the installation of outdoor unit When installing the indoor unit refer to the installation manual of indoor unit Ple...

Page 2: ...fety Precauti ons Cautions Warnings for using R290 R32 refrigerant only Preparations Install ation Operati on Maintenance Faults Diagnosis Design and Compliance Notes Sociabl e Remark 2 3 4 8 9 12 15...

Page 3: ...ause electrical components to short circuit DO NOT install the unit in a location that may be exposed to combustible gas as this could cause re The unit has wheels to facilitate moving Make sure not t...

Page 4: ...raffic area and where it will not be tripped over Do not operate unit with a damaged cord plug power fuse or circuit breaker Discard unit or return to an authorized service facility for examination an...

Page 5: ...ce or burn Be aware that the refrigerants may not contain an odour Appliance MPPDB 12CRN7 QB6G1 should be installed operated and stored in a room with a floor area larger than 11 m Appliance MPPDB 10C...

Page 6: ...ll possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which flammable refrigerant can possi...

Page 7: ...may not be adequate or Warnings for using R290 R32 refrigerant only 6 may need re calibration Detection equipment shall be calibrated in a refrigerant free area Ensure that the detector is not a pote...

Page 8: ...When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders e...

Page 9: ...outlet lower air filter lower air intake drain outlet 8 f ro n t rear control panel handle both sides horizontal louver blade swing automatically Caster power plug socket power cord buckle vent contro...

Page 10: ...on location should meet the following requirements Make sure that you install your unit on an even surface to minimize noise and vibration The unit must be installed near a grounded plug and the Colle...

Page 11: ...use the bolt to fasten the window sliders once they are adjusted to the proper length 3 For some models if the length of the window requires three window sliders optional use two bolts to fasten the...

Page 12: ...the exhaust system works properly All the illustrations in this manual are for explanation purpose only Your air conditioner may be slightly different The actual shape shall prevail max 120cm or 47 in...

Page 13: ...COOL mode light FAN mode light DRY mode light AUTO mode light WIRELESS light NOTE Some features ION FOLLOW ME HEAT WIRELESS etc are optional ION is not applicable for R32 R290 units Operation 12 NOTE...

Page 14: ...tion press and hold the swing button for 3 seconds to initiate the Wireless connection mode The LED DISPLAY shows AP to indicate you can set Wireless connection If connection router is successful with...

Page 15: ...the UP or DOWN button to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The system will...

Page 16: ...flow smoothly See Figs with Do never let it up See Figs with When the continuous drain hose is not used ensure that the corresponding drain plug and knob are installed firmly to prevent leakage X Mai...

Page 17: ...ter according to instructions This sound is caused by the ow of refrigerant inside the unit This is normal Maintenance Tips Clean the Unit Store the unit when not in use Be sure to clean the air lter...

Page 18: ...wall exhaust adaptor A as shown in the Installation section of this manual Unit Temperature Range NOTE To be in compliance EN 61000 3 11 the product MPPDB 12HRN7 QB6G1 shall be connected only to a su...

Page 19: ...cipality has established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at lea...

Reviews: