6
T-305
2.1.3 Evaporator Section
The evaporator section (Figure 2) contains the returnair
temperature sensor, thermostatic expansion valve,
dual-speed evaporator fans (EM1 and EM2),
evaporator coil and heater, drain pan heater, defrost
heaters, defrost temperature sensor, heat termination
thermostat, and heat exchanger.
The evaporator fans circulate air through the container
by pulling it in the top of the unit, directing it through the
evaporator coil, where it is heated or cooled, and
discharging it at the bottom.
The evaporator components are accessible by
removing the upper rear panel (as shown in the
illustration) or by removing the front access panels.
14
13
11
12
1
2
3
4
5
7
8
10
15
16
9
6
HTT Alternate Location
1. Evaporator Fan Motor #1
2. Humidity Sensor
3. Return Air Temperature Sensor
4. Evaporator Fan Motor #2
5. Defrost Temperature Sensor
6. Heater Termination Thermostat
7. Evaporator Coil
8. Drain Pan Heater
9.
Thermostatic Expansion Valve
10. Heat Exchanger
11. Interrogator Connector (Rear)
12. USDA Probe Receptacle PR2
13. USDA Probe Receptacle PR1
14. USDA Probe Receptacle PR3
15. Cargo Probe Receptacle PR4
16. Evaporator Coil Heaters
Figure 2. Evaporator Section
Summary of Contents for 69NT40-489-100 Series
Page 2: ......
Page 4: ......
Page 14: ...Safety 10 T 305...
Page 28: ...4 T 305...
Page 40: ...16 T 305...
Page 50: ...26 T 305 Figure 12 Standard Configuration Report...
Page 112: ...88 T 305...
Page 164: ...140 T 305...
Page 167: ...143 T 305 Based on drawings 62 10526 Rev and 62 10736 Rev Figure 90 Electrical Schematic CA...
Page 174: ...150 T 305...