24
T-305
b. Configuration Software
The configuration software controls the recording and
alarm functions of the DataCORDER. Reprogramming
to the factory installed configuration is achieved via the
same configuration card as the unit control module
software. Changes to the software may be made made
using the Data View integration device. A listing of the
configuration variables is provided in Table 3.
Descriptions of DataCORDER operation for each
variable setting are provided in the following
paragraphs.
3.6.3 Sensor Configuration (dCF02)
Two modes of operation may be configured, the
Standard Mode and the Generic Mode.
a. Standard Mode
In the standard mode, the user may configure the
DataCORDER to record data using one of seven
standard configurations. The seven standard
configuration variables, with their descriptions, are
listed in Table 4, page 25.
The six thermistor inputs (supply, return, USDA #1, #2,
#3 and cargo probe) and the humidity sensor input will
be generated by the DataCORDER. The three
Controlled Atmosphere inputs will be read over a
network from the controlled atmosphere control
module. The controlled atmosphere readings will be the
oxygen, carbon dioxide and nitrogen levels. An example
of a report using a standard configuration is shown in
Figure 12, page 26.
NOTE
The supply and return sensors used by the Da-
taCORDER software are not the same sensors
used by the temperature control software.
Table 3. DataCORDER Configuration Variables
CONFIGURATION NO.
TITLE
DEFAULT
OPTION
dCF01
(Future Use)
----
----
dCF02
Sensor Configuration
2
2,5,6,9,54,64,94
dCF03
Logging Interval (Minutes)
60
15,30,60,120
dCF04
Thermistor Format
Short
Low, Normal
dCF05
Thermistor Sampling Type
A
A,b,C
dCF06
Controlled Atmosphere/Humidity Sampling Type
A
A,b
dCF07
Alarm Configuration USDA Sensor 1
A
Auto, On, Off
dCF08
Alarm Configuration USDA Sensor 2
A
Auto, On, Off
dCF09
Alarm Configuration USDA Sensor 3
A
Auto, On, Off
dCF10
Alarm Configuration Cargo Sensor
A
Auto, On, Off
Summary of Contents for 69NT40-489-100 Series
Page 2: ......
Page 4: ......
Page 14: ...Safety 10 T 305...
Page 28: ...4 T 305...
Page 40: ...16 T 305...
Page 50: ...26 T 305 Figure 12 Standard Configuration Report...
Page 112: ...88 T 305...
Page 164: ...140 T 305...
Page 167: ...143 T 305 Based on drawings 62 10526 Rev and 62 10736 Rev Figure 90 Electrical Schematic CA...
Page 174: ...150 T 305...