103
T-305
CODE
DESCRIPTION
TITLE
TYPE
Cd16
Display/
Reset
Hours Since Compressor Service
Records total hours of air compressor run time. Hold the
ENTER key for five seconds to reset to “0”.
Cd17
Display/
Reset
Hours Since Filter Change
Displays the number of hours that have elapsed since the
membrane air filters were changed. Records actual hours
(ie. 100 hours is displayed as 100). Hold ENTER key for
five seconds to reset to “0”.
Cd18
Display
Total Run Hours
Records the total number of operational hours for the CA
system air compressor. Records total hours in increments
of 10 hours. (i.e. 3000 hours displayed as 300)
Output Codes
Cd19
Display
Air Compressor State (AC)
Displays the current operating status of the air
compressor (ON or OFF).
Cd20
Display
Air Heater State (AH)
Displays the current operating status of the air heater (ON
or OFF).
Cd21
Display
Air Heater SSR PWM Valve
(AT)
Displays the current operating status of the PWM (Pulse
Width Modulation) signal that is driving the air heater. The
number displayed is a percentage of 100.
Cd22
Display
Sample Air Solenoid Valve
State (SAV)
Displays the current operating status of the sample air
solenoid valve (OPEN or CLOSED).
Cd23
Display
Air Calibration Solenoid Valve
State (ASV)
Displays the current operating status of the air calibration
solenoid valve (OPEN or CLOSED).
Cd24
Display
Gas Calibration Solenoid Valve
State (GSV)
Displays the current operating status of the gas calibration
solenoid valve (OPEN or CLOSED).
Cd25
Display
N
2
Sample Solenoid Valve
State (NSV)
Displays the current operating status of the nitrogen
sample solenoid valve (OPEN or CLOSED).
Cd26
Display
Oxygen Solenoid Valve State
(OSV)
Displays the current operating status of the oxygen
solenoid valve (OPEN or CLOSED).
Cd27
Display
Nitrogen Purity Valve State
(NPV)
Displays the current operating status of the nitrogen purity
valve (OPEN or CLOSED).
Cd28
Display
Drain Valve Solenoid State
(DS1 and DS2)
Displays the current operating status of the drain solenoid
valve
−
#1 & #2 (OPEN or CLOSED).
Cd29
Display
CO
2
Input Solenoid Valve State
(CSV)
Displays the current operating status of the carbon
dioxide solenoid valve (OPEN or CLOSED).
Cd30
Display
Door Lock Solenoid State (DIS) Displays the current operating status of the door interlock
solenoid (OPEN or CLOSED).
Cd31
Display/
Select
CO
2
Concentration in
Calibration Gas
Gives the operator the ability to select the purity level of
the CO
2
gas being used for calibration. (5%, 20%, OFF)
Cd32
Display/
Select
CA Monitor Mode
Monitor mode provides the ability to monitor CO
2
and O
2
levels while the atmosphere inside the container is not
controlled. CO
2
Zero and O
2
Air Calibrations will be
prohibited. (IN/OUT)
Cd33
future
future
future
Cd34
Display/
Select
O
2
Lower Setpoint Limit Enable
In the ON position, the O
2
lower setpoint limit is 2.5% with
a default setting of 2.5%.
In the OFF position, the O
2
lower setpoint limit is 1% with
a default setting of 2%.
The unit will default with the loading of operational
software.
Summary of Contents for 69NT40-489-100 Series
Page 2: ......
Page 4: ......
Page 14: ...Safety 10 T 305...
Page 28: ...4 T 305...
Page 40: ...16 T 305...
Page 50: ...26 T 305 Figure 12 Standard Configuration Report...
Page 112: ...88 T 305...
Page 164: ...140 T 305...
Page 167: ...143 T 305 Based on drawings 62 10526 Rev and 62 10736 Rev Figure 90 Electrical Schematic CA...
Page 174: ...150 T 305...