25
T-305
b. Generic Mode
The generic recording mode allows user selection of the
network data points to be recorded. The user may select
up to a total of eight data points for recording. A list of the
data points available for recording follows. Changing the
configuration to generic and selecting which data points
to record may be done using the Carrier Transicold Data
Retrieval Program.
1. Control mode
2. Control temperature
3. Frequency
4. Humidity
5. Phase A current
6. Phase B current
7. Phase C current
8. Main voltage
9. Suction modulation valve percentage
10. Discrete outputs (Bit mapped -- require special
handling if used)
11. Discrete inputs (Bit mapped -- require special
handling if used)
12. Ambient sensor
13. Compressor suction sensor
14. Compressor discharge sensor
15. Return temperature sensor
16. Supply temperature sensor
17 Defrost temperature sensor
18. Discharge pressure transducer
19. Suction pressure transducer
20. Condenser pressure transducer
21. Controlled Atmosphere (CA) oxygen
concentration
22. CA carbon dioxide concentration
23. CA nitrogen concentration
24..CA return temperature
25. CA membrane temperature
26. CA discrete inputs
27. CA discrete outputs
Table 4. DataCORDER Standard Configurations
Standard
Config.
Description
2 sensors
(dCF02=2) 2 thermistor inputs(supply & return)
5 sensors
(dCF02=5)
2 thermistor inputs(supply & return)
3 USDA thermistor inputs
6 sensors
(dCF02=6)
2 thermistor inputs(supply & return)
3 USDA thermistor inputs
1 humidity input
9 sensors
(dCF02=9)
2 thermistor inputs(supply & return)
3 USDA thermistor inputs
3 Controlled Atmosphere inputs
1 humidity input
6 sensors
(dCF02=54)
2 thermistor inputs(supply & return)
3 USDA thermistor inputs
1 cargo probe (thermistor input)
7 sensors
(dCF02=64)
2 thermistor inputs(supply & return)
3 USDA thermistor inputs
1 humidity input
1 cargo probe (thermistor input)
10 sensors
(dCF02=94
)
2 thermistor inputs(supply & return)
3 USDA thermistor inputs
3 Controlled Atmosphere inputs
1 humidity input
1 cargo probe (thermistor input)
Summary of Contents for 69NT40-489-100 Series
Page 2: ......
Page 4: ......
Page 14: ...Safety 10 T 305...
Page 28: ...4 T 305...
Page 40: ...16 T 305...
Page 50: ...26 T 305 Figure 12 Standard Configuration Report...
Page 112: ...88 T 305...
Page 164: ...140 T 305...
Page 167: ...143 T 305 Based on drawings 62 10526 Rev and 62 10736 Rev Figure 90 Electrical Schematic CA...
Page 174: ...150 T 305...