![background image](http://html1.mh-extra.com/html/carrier/69nt40-489-100-series/69nt40-489-100-series_operation-and-service-manual_2563838034.webp)
10
T-305
2.1.7 Control Box Section
The control box (Figure 6) includes the manual
operation switches, circuit breaker (CB-1), compressor,
fan and heater contactors, control power transformer,
fuses, key pad, display module, current sensor module,
refrigeration controller module and the communications
interface module.
2.1.8 Communications Interface Module
The communications interface module is a slave
module which allow communication with a master
central monitoring station. The module will respond to
communication and return information over the main
power line. Refer to the master system technicalmanual
for further information.
19
20
21
15
17
18
1
2
3
4
5
6
7
10
9
22
11
14
8
12
13
16
1. Compressor Contactor
2. Heater Contactor
3. Display Module
4. Communications Interface Module
5. Controller/DataCORDER Module (Controller)
6. Key Pad
7. Emergency Defrost Light
8. Start-Stop Switch
9. Remote Monitoring Receptacle
10. Manual Defrost Switch
11. Condenser Fan Switch
12. Emergency Defrost Switch
13. Emergency Defrost Fuse
14. Emergency Bypass Switch
15. Controller Battery Pack
16. Interrogator Connector (Box Location)
17. Control Transformer
18. Evaporator Fan Contactor - High Speed
19. Evaporator Fan Contactor - Low Speed
20. Condenser Fan Contactor
21. Circuit Breaker -- 460V
22. Current Sensor Module
Figure 6. Control Box Section
Summary of Contents for 69NT40-489-100 Series
Page 2: ......
Page 4: ......
Page 14: ...Safety 10 T 305...
Page 28: ...4 T 305...
Page 40: ...16 T 305...
Page 50: ...26 T 305 Figure 12 Standard Configuration Report...
Page 112: ...88 T 305...
Page 164: ...140 T 305...
Page 167: ...143 T 305 Based on drawings 62 10526 Rev and 62 10736 Rev Figure 90 Electrical Schematic CA...
Page 174: ...150 T 305...