Table 5 – Additional Subcooling Required -- Model 25H**5

Subcooling Delta from Rating Plate Value

Outdoor Unit Tonnage

Indoor Unit | Additional Subcooling Required

18

24

30

36

42

48

60

CAP**1814AL*

---

CAP**2414AL*

---

CAP**3014AL*

---

CAP**3614AL*

---

CAP**4221AL*

---

CAP**4817AL*

---

CAP**6021AL*

---

CAP**2414AL*

---

CAP**2417AL*

---

CAP**3017AL*

---

CAP**3617AL*

---

CAP**4224AL*

---

CAP**4821AL*

---

CAP**6024AL*

---

CAP**2417AL*

---

CAP**2517AL*

+5

CAP**3614AL*

---

CAP**3621AL*

---

CAP**4321AL*

+5

CAP**4824AL*

---

CAP**6124AL*

---

CNPV*1814AL*

---

CAP**3014AL*

---

CAP**3617AL*

---

CAP**4221AL*

---

CAP**4817AL*

+5

CAP**6021AL*

---

CNPV*6024AL*

---

CNPV*2414AL*

---

CAP**3017AL*

---

CAP**3621AL*

---

CAP**4224AL*

---

CAP**4821AL*

+3

CAP**6024AL*

---

CSPH*6012AL*

---

CNPV*2417AL*

---

CNPV*2414AL*

---

CAP**3717AL*

+5

CNPV*3617AL*

---

CAP**4824AL*

+3

CAP**6124AL*

+3

FB4CNP060L

---

CSPH*2412AL*

---

CNPV*2417AL*

---

CAP**3721AL*

+5

CNPV*3621AL*

---

CNPV*4217AL*

---

CNPV*4821AL*

---

FV4CNB006L

---

FB4CNF018L

---

CNPV*3014AL*

---

CNPV*3014AL*

---

CNPV*4217AL*

---

CNPV*4221AL*

---

CNPV*4824AL*

---

FX4DN(B,F)061L

---

FB4CNF024L

---

CNPV*3017AL*

---

CNPV*3017AL*

---

CNPV*4221AL*

---

CNPV*4821AL*

---

CNPV*6024AL*

---

FB4CNP018L

---

CSPH*2412AL*

---

CNPV*3617AL*

---

CSPH*3612AL*

---

CNPV*4824AL*

---

CSPH*4812AL*

---

FB4CNP024L

---

CSPH*3012AL*

---

CNPV*3621AL*

---

CSPH*4212AL*

---

CSPH*4212AL*

---

CSPH*6012AL*

---

FFMANP018

---

FB4CNF030L

---

CSPH*3012AL*

---

FB4CNF036L

---

CSPH*4812AL*

---

FB4CNF048L

---

FFMANP019

---

FB4CNP030L

---

CSPH*3612AL*

---

FB4CNF042L

---

FB4CNF042L

---

FB4CNP048L

---

FFMANP024

---

FFMANP024

---

FB4CNF030L

---

FB4CNP036L

---

FB4CNF048L

---

FB4CNP060L

---

FFMANP025

---

FFMANP025

---

FB4CNF036L

---

FB4CNP042L

---

FB4CNP042L

---

FV4CN(B,F)005L

---

FPMAN*018

---

FFMANP030

---

FB4CNP030L

---

FFMANP036

---

FB4CNP048L

---

FV4CNB006L

+3

FPMAN*024

---

FFMANP031

---

FB4CNP036L

---

FFMANP037

---

FV4CN(B,F)003L

---

FX4DN(B,F)049L

---

FPMBN*018

---

FPMAN*024

---

FFMANP030

---

FPMAN*036

---

FV4CN(B,F)005L

+3

FX4DN(B,F)061L

+3

FPMBN*024

---

FPMAN*030

---

FFMANP031

---

FV4CN(B,F)003L

---

FV4CNB006L

+5

FV4CN(B,F)003L

---

FPMBN*024

---

FFMANP036

---

FV4CN(B,F)005L

+3

FX4DN(B,F)043L

---

FV4CNF002L

---

FPMBN*030

---

FFMANP037

---

FV4CNB006L

+5

FX4DN(B,F)049L

+3

FX4DNF019L

---

FV4CN(B,F)003L

---

FPMAN*030

---

FV4CNF002L

---

FX4DN(B,F)061L

+5

FX4DNF025L

---

FV4CNF002L

---

FPMAN*036

---

FX4DN(B,F)037L

---

FX4DN(B,F)031L

---

FPMBN*030

---

FX4DN(B,F)043L

---

FX4DN(B,F)037L

+5

FV4CN(B,F)003L

---

FX4DN(B,F)049L

+3

FX4DNF025L

---

FV4CN(B,F)005L

+5

FV4CNF002L

---

FX4DN(B,F)031L

---

FX4DN(B,F)037L

+3

FX4DN(B,F)043L

+3

Note

: 37 Size model does not require any subcooling adjustment for various indoor matches.

Table 6 – Required Liquid Line Temperatures

_

F

LIQUID PRESSURE AT

SERVICE VALVE (PSIG)

REQUIRED SUBCOOLING TEMPERATURE (° F)

8

10

12

14

16

18

251

76

74

72

70

68

66

259

78

76

74

72

70

68

266

80

78

76

74

72

70

274

82

80

78

76

74

72

283

84

82

80

78

76

74

291

86

84

82

80

78

76

299

88

86

84

82

80

78

308

90

88

86

84

82

80

317

92

90

88

86

84

82

326

94

92

90

88

86

84

335

96

94

92

90

88

86

345

98

96

94

92

90

88

354

100

98

96

94

92

90

364

102

100

98

96

94

92

374

104

102

100

98

96

94

384

106

104

102

100

98

96

395

108

106

104

102

100

98

406

110

108

106

104

102

100

416

112

110

108

106

104

102

427

114

112

110

108

106

104

439

116

114

112

110

108

106

450

118

116

114

112

110

108

462

120

118

116

114

112

110

474

122

120

118

116

114

112

486

124

122

120

118

116

114

499

126

124

122

120

118

116

511

128

126

124

122

120

118

Summary of Contents for 25HPB6

Page 1: ...suitable warning label EXPLOSION HAZARD Failure to follow this warning could result in death serious personal injury and or property damage Never use air or gases containing oxygen for leak testing o...

Page 2: ...ications Clearance Requirements When installing allow sufficient space for airflow clearance wiring refrigerant piping and service Allow 24 in 609 6 mm clearance to service end of unit and 48 in 1219...

Page 3: ...rements Refer to Table 2 for field tubing diameters There are no buried line applications greater than 36 in 914 4 mm If refrigerant tubes or indoor coil are exposed to atmosphere they must be evacuat...

Page 4: ...valves with a heat sinking material such as a wet cloth Braze joints using a Sil Fos or Phos copper alloy Table 2 Refrigerant Connections and Recommended Liquid and Vapor Tube Diameters In UNIT SIZE...

Page 5: ...hrough power wiring hole provided and into unit control box Connect Ground and Power Wires WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death The u...

Page 6: ...tem caps after system is opened to refrigerant flow back seated Replace caps finger tight and tighten with wrench an additional 1 12 turn 3 Close electrical disconnects to energize system 4 Set room t...

Page 7: ...up To initiate a forced defrost speedup pins J1 must be shorted with a flat head screwdriver for 5 seconds and RELEASED If the defrost thermostat is open a short defrost cycle will be observed actual...

Page 8: ...r temperature is below 70_F 21 11_C or the outdoor temperature is not in the favorable range adjust charge for line set length above or below 15ft 4 57 m only Charge level should then be appropriate f...

Page 9: ...MANP036 FB4CNP048L FV4CNB006L 3 FPMAN 024 FFMANP031 FB4CNP036L FFMANP037 FV4CN B F 003L FX4DN B F 049L FPMBN 018 FPMAN 024 FFMANP030 FPMAN 036 FV4CN B F 005L 3 FX4DN B F 061L 3 FPMBN 024 FPMAN 030 FFM...

Page 10: ...psig low side with 550 psig low side retard S Use hoses with 700 psig service pressure rating S Leak detectors should be designed to detect HFC refrigerant S Puron as with other HFCs is only compatib...

Reviews: