4. While the unit is in stop mode, insert a piece of cable into the wire guide bushing
and push the trapped slug through the end of the guide bushing, into the debris
tray.
5. After the trapped slug has been pushed out of the guide bushing, remove the
cable from the wire guide bushing.
6. Press
.
7. The unit will enter auto calibration mode and prepare for a new strip cycle.
8. The Model 75 is ready to continue processing cables.
5
.
4 Notes on Processing Cables
•
The Model 75 will not process cables without the safety guard installed.
•
Insert cable all the way through the wire guide bushing until it stops against the
blade.
•
Make sure no slugs get trapped in the end of the wire guide bushing at the end of
the cycle.
•
Never insert an object (other than a cable to be stripped) into the wire guide
bushing.
•
Never force a trapped slug through the wire guide bushing.
•
To stop a strip cycle, press and release the Run/Stop switch.