Carpenter Model 75 Compu-Strip®
Carpenter Model 75 Compu
-
Strip
®
•
Phone
: (315) 682-
9176 •
Fax
: (315) 682-9160
Website
: www.carpentermfg.com •
Revised June 10
th
, 2019
Page 21
Figure 3
-
6
: Guide Bushing and Retaining Screw
To install a wire guide bushing:
1. Remove the Lexan safety guard from the Model 75.
2. Insert the narrow end of the desired guide bushing into the brass guide bushing
block until the shoulder at the front of the bushing stops against the bushing
block. Securely tighten the thumb screw against the bushing. See Figure 3-7
below.
3. Replace the Lexan safety cover.
4. Be sure to enter the wire guide size that is marked on its face into the
GUIDE
5. To remove the wire guide bushing, reverse steps 1
–3 above.
Note
: If the longest programmed strip length is less than 0.500” (12.7mm), it may be
difficult to change the wire guide bushing. If this occurs:
1.
Temporarily program the longest strip length to 1.500” (38.1mm).
Mode for information on programming
2. Install the wire guide bushing. See steps 1
–5 above.
3. Reprogram the correct length change in step 1 above.
Retaining
Thumb Screw
Wire Guide
Bushing
Brass Guide
Bushing Block