Interface Module Hardware
DYNAFLOW
SPECIFICATIONS
Pneumatic Requirements
Transducers:
The air supplied to the transducers must be clean and dry and meet the following
general specifications:
Filtration:
20 Micron
Supply Pressure:
90 PSIG min. to 150 PSIG max.
Volume:
0.04 to 0.13 Cv
Operating Temperature:
32
o
to 150
o
F (0
o
to 65.5
o
C)
Control Rack (Up to 8 Channels Per 1/2 of 19" Rack)
Dimensions:
83mm H X 250mm W X 184mm D standard half rack
Power Requirements:
24 VDC at 1 Amp typical, all 8 CHANNELs installed
The following must be followed if the flow control rack and/or Operator Interface is to be integrated into a larger system
control panel:
- The 24 VDC Power Supply must be located in the same control panel as the fluid flow control.
-
DO NOT
use a central power supply located else where. The power supplies may be sized for and used for other controls
within the same cabinet
WITH THE EXCEPTION OF HIGH VOLTAGE POWER SUPPLY CONTROLLERS
. High voltage
power supply controllers MUST have a dedicated power supply.
General:
This Module is responsible for local display/keyboard control and communication
to the Host controller. Responsible also for non-volatile storage of all JOB data
tables and system configuration parameters.
Dimensions:
3U (130.5 mm) H x 7H (35.2 m) W standard 19” rack module
Digital Inputs:
24 VDC at 2.3 ma typical per input (optically isolated, source by default, sink selectable)
- JOB Select Strobe
- JOB Select 1 (lower significant BCD digit)
- JOB Select 2
- JOB Select 4
- JOB Select 8
- JOB Select 10 (middle significant BCD digit)
- JOB Select 20
- JOB Select 40
- JOB Select 80
- JOB Select 100 (upper significant BCD digit)
- System Ready/Halt
- Global Gun Enable
Digital Outputs:
24 VDC sourced at 300 ma maximum per output (Solid state relay contacts)
System Pulse:
Used as watchdog timer by an external supervisory PLC or computer.
System Fault:
Used to activate an alarm and to supply a signal remotely that a System, GUN, or other
fault has occurred.
(Continued On Next Page)
LN-9400-00-R11 (08/2018)