Mechanical Adjustments
Applicator APL 100
34 Operating
Manual
11/13
1. Loosen
screw
(2).
2. Shift the cylinder unit including the pad (4) inside the elongated
hole in such a way, that the dispensed label is aligned centrally to
the pad respectively to the open holes in an universal pad.
3. Tighten screw (2).
NOTICE!
Check the adjustment with compressed air switched on.
7.2 Adjusting the Parallelism between Pad and
Dispense Edge
1
2
3
Figure 18
1. Loosen
screw
(1).
2. Adjust the parallelism between the rear edge of the pad (2) and
the dispense edge (3) by turning the pad.
3. Tighten screw (1).
Side adjustment