Installation
Applicator APL 100
22 Operating
Manual
11/13
4.4 Preparing for Using a Sprint-Mounted Tamp Pad
NOTICE!
For using a spring-mounted universal tamp pad (> 90 x 90 mm)
the fitting of the cylinder unit must be changed.
The cylinder unit (6) can be mounted on the bracket (1) in two
different positions.
When the applicator is delivered, the cylinder unit is mounted on the
bracket using the upper threaded hole (4). That position is suitable for
the most pads.
1
2
3
4
5
6
Figure 11
1. Loosen the screw (3) and washer (2).
2. Dismount the cylinder unit (6) from the connecting bracket.
3. Fix the cylinder unit (6) with the screw (3) at the connecting
bracket (1) by using the lower threaded hole (5).