“UEX-PLUS” +030220621 - rel. 1.4 - 04.08.2009
Table of water circuit, electrical and electronic spare parts, UE090 to
UE130
description
spare part code
position
fi g.
UE090
UE130
Water circuit
Drain pump hose
UEKDH00000
7
11.e
Manifold UEKCOLL000
6
11.e
Drain pump kit
KITPSE0000
5
11.e
Internal tubing kit
UEKT100XXL
3
11.e
Double check valve kit
FWHDCV0000
-
Conductivity meter kit
KITCN00000
4
11.e
Fill solenoid valve kit
KITVC10140
2
11.e
Drain circuit
UEKDC20000
1
11.e
Electrical and electronics
Display terminal
HCT1EXW000
18
11.f
TAM (current transformer)
UEKTAM0000
11
11.f
Contactor
URKCONT300
11.f
Power transformer
UEKTR20000
11
11.f
Electronic controller
(1)
HCzXxxxvi0
(2)
14
11.f
Fuse carrier
URKFH20000
13
11.f
Pump control relay
UEKDT00000
12
11.f
F1 - F2 power fuses
UEKFUSE300
-
see electrical diagram
F3 Pump fuse
URKFUSE300
-
see electrical diagram
F4 Transformer secondary fuse
UEKFUSE400
-
see electrical diagram
Connection cable between terminal and electronic controller
S90CONN002
-
Tab. 11.f
(1)
To make an order specify the complete product code and the serial
number of your humidifer.
(2)
z: board version (A: basic version up to UE65;
B: with espantion board for UE90-130)
XX: kg/h (01...130)
v:
voltage
i: 0 single packing; 1: multiple packing
Table of spare parts for standard and special cylinders UE090 to
UE130
Description
UE090
UE130
STANDARD disposable cylinders
400 V 3ph cylinder, conductivity 350 to 1250 μS/cm
BL0T4C00H2
BL0T5C00H0
SPECIAL disposable cylinders
400 V 3ph cylinder, conductivity 75 to 350 μS/cm
BL0T4B00H2
BL0T5B00H0
SPECIAL openable cylinder
400 V 3ph cylinder, conductivity 75 to 350 μS/cm
BLCT4B00W2
BLCT5B00W0
400 V 3ph cylinder, conductivity 350 to 1250 μS/cm
BLCT4C00W2
BLCT5C00W0
Electrode and gasket kit
400 V 3ph cylinder, conductivity 75 to 350 μS/cm
KITBLCT4B2
KITBLCT5B2
400 V 3ph cylinder, conductivity 350 to 1250 μS/cm
KITBLCT4C2
KITBLCT5C2
Gasket and fi lter kit
KITBLC4FG0
KITBLC5FG0
Tab. 11.g
11.4 Cleaning and maintenance of the cylinder
Replacement
Important: the cylinder must be only be replaced by qualifi ed
personnel, and with the humidifi er unplugged from the power
supply.
In normal conditions, the disposable cylinders should be replaced after
one year (or 2500 hours of operation, if cleaned periodically), while the
openable cylinders last 5 years (or 10,000 hours of operation, if cleaned
periodically). They must be replaced immediately – even before the
specifi ed intervals – if any anomalies occur. For example, when the lime
scale inside the cylinder prevents the correct fl ow of electric current.
Replacement procedure:
empty all the water (cylinder replacement procedure, see
1.
maintenance menu);
turn off the humidifi er (switch “0”), and open the mains disconnect
2.
switch on the power supply (safety procedure);
wait for the humidifi er and the cylinder to cool down;
3.
remove the front cover;
4.
disconnect the electrical cables from the cylinder and steam hose;
5.
release the cylinder from the locking device and lift it to remove it;
6.