20L Dehumidifier 

8902

Instructions

Operating Principle

Humid air is drawn into the unit and cooled. Water droplets condense and drop
into the water tank. Dried air is then released back into the room.

Operating Instructions

1. 

To start.

Unpack the unit. Ensure the air outlet grill on the top of the unit is

open and plug into a wall plug. The buzzer sounds once and the run light will
blink. Press the on/off button once and the run light will be on, the continuous
light will be on and the humidity /time display window will show the current
reading. To switch off, press the on/off button once, note the fan will still be
heard for a few seconds afterwards.

2. 

To set the humidity level.

Press the up or down arrow to the level you

require. Humidity can be set between RH26% and RH90% (note the actual
humidity measured is approximate). If the level is set below 26, the reading
will show CO and will dehumidify continuously. If the set humidity is higher
than the current actual humidity the unit will not start operating until it
becomes lower.

3. 

To set the timer to switch on the machine.

Press the on button and

press the timer on button once. The timer on light will blink and the
humidity/time display will show 00. The timer can be set for 0 to 24 hours, in
multiples of 1 hour. Press the up button for the number of hours in the future
you want the unit to turn on. e.g. select 2 for 2 hours time. The timer on light
will be on. To cancel the setting, press the timer on button again and the timer
on light will go out. The unit will now turn on automatically at your desired
time. 

4.

To set the timer to turn off the machine.

Press the timer off button and

the timer off light will blink. The humidity/time display will show 00. Press the
up button for the number of hours in the future you want the unit to turn off.
e.g. select 2 for 2 hours time. The timer off light will be on. To cancel the
setting, press the timer on button again and the timer on light will go out. The
unit will now turn off automatically at your desired time. 

5. The timer settings will need to be set each time the unit is operated as there is

no memory function. You may set a time on only, a time off only or a time on
followed by a time off.

6. 

Display error codes.

If the humidity/time display shows E1, E2 or E3, the

unit is detecting an error. E1 shows that the temperature sensor is faulty, E2
the humidity sensor is faulty, and E3 is low gas sensor.  If these error messages
occur, try unplugging the unit and start again. If they still show, the unit is
faulty and should not be used.

Operation panel

Air inlet grill

Water tank

Air outlet grill

Handles

Filter

Wheels

Cord hanger

Continuous drainage outlet

Main cord

Operation panel