12
prodotti Technocity
EL3024
29-05-200
1
DI0187
Description
:
Product Code
:
Date
:
Drawing number
:
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - v
ia Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rig
hts reserved. Unauthorised copying or use of the information contained in this document is punishable by law
INSTALLAZIONE A DESTRA
OPENING THE ACCESS DOOR (fig.8)
To open the door giving access to the internal components loosen
the two grub screws "
E
" (situated laterally in the top corners) using
a 3 mm hexagonal key.
Open the access door and if necessary pull upwards to release it
from the two plastic hinges "
F
" located at the bottom.
Attention!
Be careful because the warning lamp bulb is fastened
on the inner side of the access door ( see "warning light" instruc-
tions).
To close the door, insert the two plastic hinges, located at the
bottom, into the grooves on the access door and when the sides are
flush fitting to the cabinet fasten down the two grub screws "
E
".
OPENING THE TOP COVER (fig.7)
After having opened and removed the front access panel, loosen
the grub screw "
H
" and lower the plate "
G
". Using a posidrive
screwdriver "
M
" remove the two self-tapping screws "
L
" and
dismantle the top cover.
ASSEMBLING THE BOOM (fig.5)
Work out the orientation of the hub (pos 2, fig.2) depending on
which direction the barrier has to open:
- closing to the left (fig.5A);
- closing to the right (fig.5B);
Fasten down the hub "
N
" to the bar holder arm using the screw
"
P
".
Insert the hub of the bar holder arm onto the threaded shaft "
Q
" of
the geared motor, keeping the bar in a vertical position.
Using a rubber mallet make sure the hub is well fastened down
and tighten into place using the screw "
J
" (M8x35).
Fastening torque
30Nm
.
With a hexagonal key fasten the hub to the threaded shaft using
the screw "
R
" (fig. 5A, 5B). Fastening torque
30Nm
.
ADJUSTING THE OPENING/CLOSING TRAVEL LIMITS
The deceleration microswitches have been factory set as described
in note B pag.7 of the instruction manual ZVL411.02 (referring to
the electronic programmer) supplied together with this manual.
Therefore if the barrier is to be positioned to the right of the pas-
sageway no adjustment is necessary.
It may be necessary to adjust the mechanical stops "
T
" and "
U
"
(fig.6) of the lever "
S
" with the bar in a vertical position
90°
and in
a horizontal position
0°
.
Therefore if the barrier is to be positioned to the left of the pas-
sageway the deceleration cam will have to be repositioned as well
as adjusting the mechanical stops "
T
" and "
U
". Read the paragraph
"POSITIONING THE UNIT"
Releasing the gate should only be carried out when the motor has
stopped because of blackouts.
Remove the front panel (fig.8) to access the release mechanism.
See instructions "Opening the access door".
Releasing the bar
Press the lever "
V
" until it reaches the released position (fig.9B)
where it will remain thanks to an anti return mechanism.
Attention!
The boom is not balanced and must be held
during manual release
Locking the bar
Slightly force the lever "
V
" from the release position to overcome
the anti return mechanism.
The return to the blocked position (fig.9B) is carried out auto-
matically by a spring. The cogs within the geared motor may not
necessarily slot together straight away.
They can however easily be locked together by moving the bar
slightly.
The appliance is factory assem-
bled for an installation to the
right
of the passageway. For
installations to the
left
of the
passageway invert the motor
power supply cables (pos. "
CN3
")
and the travel limit cables (pos. "
10
"
and "
11
") while the travel limit neutral wire
remains in the same position.
• Carry out several trial manoeuvres in the "MANUAL" mode to
make sure the barrier works correctly. (see instruction manual
ZVL411.02).
FITTING THE CORD TO THE ACCESS DOOR (fig.10)
To make sure the access door doesn’t accidentally fall after it has
been opened you have to wire a piece of cord (supplied with the
appliance) between the cabinet and the door. To assemble it pro-
ceed as follows:
- first of all assemble the cord as shown in figure "
10A
" and "
10B
"
with the two identical grips "
W
" and "
X
" which can be loosened
or tightened using the self-tapping 3,5x13 screw pos. "
Z
";
- fasten the end "
W
" to the barrier cabinet e.g. to the right-hand
upright as indicated by the arrow in the drawing;
- then fasten the other end "
X
" to the rib structure of the access
door.
CUTTING THE BOOM
If the installation requires the boom to be shortened; make sure cut
the end which is not going to be inserted into the boom holder.
WARNING LIGHTS
The movement indicator light is located inside the barrier on the
middle part of the access door (fig.8, pos.K).
Lamp type: sphere bulb
24V-25W
with an E14-clear connector.
The lamp holder is fixed to the door using a clip which can easily
be extracted.
Attention!
Once you have disconnected the lamp holder lay it down
carefully in a safe position where it cannot be damaged.
Before connecting the appliance make sure that the voltage rated
on the data plate conforms to that of the mains supply.
WARNING!
An all pole trip switch with a least
3mm
between the contacts must be installed between the unit and
the mains supply.
• Connect the command and safety device wires.
• Fasten the power cable to the programmer so that both the
power wires and the sheath are well blocked by the supplied
cable clamp.
• Do not use cables with aluminium conductors; do not solder the
ends of cables which are to be inserted into the binding posts;
use cables which are marked
T min 85°C
and are resistant to
atmospheric agents.
• The terminal wires must be positioned in such a way that both
the wire and the insulating sheath are tightly fastened. You may
use a cable jubilee clip or similar.
MANUAL RELEASE MECHANISM (fig.9)
POSITIONING THE UNIT
Collegamenti scheda base
PRG850
18-03-99
DI0127
Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A
- 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
PRG850
23
22
24
20
19
21
26
25
TD
Fuse T1.6A
TB
LS 24V~
FCC
FCA
FTC_I
FTC_S
TC TA
TAL
LP 24V~
TRF 220V~
LINE 220V~
LC
220V~
L1
F1
N
L
12
11
10
9
8
7
6
5
4
3
2
1
18
17
16
15
14
13
1
2
LP
SEL
1
3
2
CLOSIN
G
COMMON
OPENIN
G
24V 12V 0
C
1
6
5
4
3
2
NA
NC
NC
C
NA
FTC-RX
1
3
2
24V
12V
0
FTC-TX
24V AC
27
28
FCA
1
2
PS
NC
NA
FCC
L5
L6
L7
L8
L4
Fuse F1A
Fuse F10
A
{
CN3
{
CN2
{
CN1
F3
F2
V1
V2
V0
V3
V4
ELECTRICAL CONNECTION (fig.11)