Once the board thickness changes, the levelling bolts will have to be adjusted. The levelling bolts are
designed to ensure the clamp plate is level (horizontal) when in the retracted position. To check if the
clamp plate is level, retract the clamp and the gap between the table and clamp plate should be the same
at the front and rear (parallel). If it is not, adjust the levelling bolt until the plate is level.
When the board thickness changes, replace the piece of o
ff
-cut with the new board under the o
ff
cut
holder, refer to Fig.7. This o
ff
-cut piece assists with clamp stabilisation and improves clamping force at
the front edge of the board.
ENSURE CLAMP PLATE IS LEVEL WHEN IN THE RETRACTED (UP) POSITION,
OTHERWISE THE PLATE CAN RUB ON THE FEED ROLLERS OR JAM UP THE BOARDS.
EM-10 / EM-12
This manual describes the machine in current produce on.
We reserve the right to change the specifications without notice.
9