![Cantek EM 12 Operation Manual Download Page 6](http://html1.mh-extra.com/html/cantek/em-12/em-12_operation-manual_3951510006.webp)
TRANSPORT
The
Cantek America
End Matcher is a precision machine and great care must be taken during
loading, unloading, and placing into position. The machine can be lifted using a forklift or crane. The
weight is about 1050 Kg. Ensure the Endprofiler is properly secured and balanced before lifting.
BEFORE LIFTING THE MACHINE, ENSURE THERE ARE NO CABLES OR AIR LINES
HANGING DOWN, WHICH COULD BE CRUSHED BY THE TINES.
INSTALLATION
1. The machine should be installed on a stable and level floor. It can be bolted to the floor if required.
2. Dust extraction - 1 x Horizontal takeo
ff
about 975mm above the floor
Diameter = 150mm (6”) Flow = at least 3,500 cfm
3. Air supply - Pressure should be 7 Bar, the machine regulates to 6 Bar.
Electrical - 3 phase 415V.
SAFETY PRECAUTIONS.
EVERY EFFORT HAS BEEN MADE TO SAFE GUARD THE OPERATOR FROM
INJURY UNDER NORMAL OPERATING CONDITIONS. PLEASE READ THE
FOLLOWING GENERAL RULES BEFORE OPERATING THE MACHINE.
1.All operators and maintenance personnel must thoroughly read and understand this manual before
operating the machine.
2.Do not operate the machine unless ALL safety guards have been replaced.
3.Do not operate the machine unless eye protection is worn at all times
4.Maintenance and repair of electrical and pneumatic controls as well as tooling changes, should be
carried out by qualified personnel - It is the responsibility of the owner of the machine to ensure that
his personnel are qualified.
5.ALWAYS turn o
ff
the power and the air supply before carrying out tool changes or maintenance work.
6.Keep hands clear of moving parts at ALL times.
7.If any abnormal problem or abnormal condition arises during operation, stop the machine
immediately and report to a supervisor.
DO NOT turn the machine on again until the problem has been rectified by qualified personnel.
8.The machine should never be left under power when not in operation or unattended.
9.Regularly check the tooling for defects and wear to ensure safe and accurate machine operation.
EM-10 / EM-12
This manual describes the machine in current produce on.
We reserve the right to change the specifications without notice.
6