Service Bulletin
Issued by Canon Europa N.V.
Model :
NP6251
No.:
6251-011 Rev. 1
(FF-T01-H2-000022-01)
DATE:
27.11.98
Location
:
FIXING ASSEMBLY
Subject
:
OPEN CIRCUIT IN SUB THERMISTOR
Reason
:
The line used in the sub thermistor can suffer an open circuit, leading to 'E000'. To prevent this
problem, the sub thermistor will be changed to another type.
Details
:
<Symptom>
'E000' is indicated and in about 5 sec, the power switch turns Off.
<Cause>
The sub thermistor suffers an open circuit.
<Factory Measures>
The sub thermistor will be changed to a new type. (See the illustrations below.)
[Old type]
[New type]
COPIER
Connector (white)
Connector (yellow)
Change in the wire paths