4. Adjusting the Left/Right Registration
Make adjustments so that the position of the image is as indicated in Figure 2-5 when
the Test Sheet is copied in Direct.
a.
Pick-Up from the Cassette
Turn the screw 1 shown in Figure 2-4 to adjust the position of the cassette hook plate.
standard: 0.±1.5 mm
clockwise turn: paper moves in the direction of – shown in Figure 2-5.
counterclockwise turn: paper moves in the direction of + in Figure 2-5.
Figure 2-4
Figure 2-5
b.
Pick-Up from the Multifeeder
Loosen the screw 1, and move the position of the tray so that it is 0 ±1.5 mm.
Figure 2-6
CHAPTER 2 STANDARDS AND ADJUSTMENTS
2-4
q
(-)
(+)
0±1.5mm