CHAPTER 2 STANDARDS AND ADJUSTMENTS
2-13
6) Tighten the screw on the pulley.
7) Detach the positioning tool (FY9-3009).
3. Adjusting the Scanner Cable Tension
Move the tension plate and tighten the screw
w
so that the distance across the ends
of the cable spring
q
is 34 ±1 mm as indicated in Figure 2-16.
Figure 2-16
4. Assembling the Mirror Positioning Tool
1)
Remove the screw found in position B.
Figure 2-17
2) Fit the screw removed in step 1) in position A, and tighten it slightly.
3) Extend the arm accommodated by the main frame unit it butts against the stopper as
in Figure 2-18.
q
w
34±1mm
A
A
B
B
Position B
Longest pin
Medium-Length pin