6. Routing the Drive Belt
Route the drive belt around the pulley and tensioner as shown in Figure 2-39.
Figure 2-39
7. Storing the Fixing Heater Resistance
You must store the resistance of the fixing heater as follows whenever you are
replacing the fixing upper unit; do not change the setting unless you have replaced the
heater.
1) Take notes of the resistance (ohm) of the fixing heater recorded on the rear side plate
of the fixing upper unit.
2) Attach the fixing upper unit to the copier.
3) Open the front door, and insert the door switch actuator into the door switch.
4) Press the service mode switch (SW302) with a hex key.
•
The copier activates service mode, and indicates ‘1’.
5) Press [3] on the keypad.
•
The copier activates adjustment mode, and indicates ‘3’.
6) Press the AE key.
•
The copier enters adjustment mode, and indicates ‘301’.
7) Press [0] and [4] on the keypad.
•
The copier indicates ‘304’.
8) Press the Start key.
•
The copier indicates the current setting.
9) Enter the measured reading, and press the AE key to store.
10) Record the new setting on the service mode label.
11) Press the Reset key.
•
The copier de-activates service mode.
unit:
ohms; enter a value which is the result of the measured resistance multiplied
by 10.
range (default)
220/240V: ..........235 to 325 (280)
CHAPTER 2 STANDARDS AND ADJUSTMENTS
2-27
Summary of Contents for NP6218
Page 5: ...1 1 1 CHAPTER 1 MAINTENANCE AND INSPECTION A Image Adjustment Basic Procedure ...
Page 6: ...1 2 B Periodical Servicing ...
Page 48: ...CHAPTER 3 ARRANGEMENT AND FUNCTIONS OF THE ELECTRICAL PARTS 3 2 A Sensors Figure 3 1 ...
Page 54: ...CHAPTER 3 ARRANGEMENT AND FUNCTIONS OF THE ELECTRICAL PARTS 3 8 D PCBs Figure 3 4 ...
Page 60: ...CHAPTER 3 ARRANGEMENT AND FUNCTIONS OF THE ELECTRICAL PARTS 3 14 ...
Page 76: ...CHAPTER 4 SERVICE MODE 4 16 ...
Page 84: ...CHAPTER 5 SELF DIAGNOSIS 5 8 ...
Page 87: ...A 3 C GENERAL CIRCUIT DIAGRAM not available ...
Page 88: ...A 4 ...