Printing Problems and Remedies
5-3
T
ro
u
b
lesho
ot
ing
5
Cause 6
An error message is displayed on the LCD display of the machine.
Remedy
After confirming the error message, see Chapter 7, “Troubleshooting,” in the
Reference Guide,
and perform the necessary operations according to the error
message displayed.
Detailed information concerning the machine cannot be set or browsed using the Remote UI
or utility.
Cause 1
The IP addresses of computers on which the Remote UI or utility is used are not
allowed by the machine.
Remedy
Check the settings for <IP Address Range>. If the machine is set to restrict the
access from the IP address of a computer, you cannot browse the machine’s
information from the computer using the Remote UI. (See “Setting the IP
Address Range,” on p. 2-38.)
Cause 2
HTTP is disabled.
Remedy
Set <Use HTTP> to ‘On’, and make sure that the same port number as set in
the machine is used on the browser. (See “Protocol Settings,” on p. 3-2.)
Cause 3
The Remote UI is disabled.
Remedy
Set <Remote UI On/Off> to ‘On’. (See Chapter 4, “System Manager Settings,” in
the
Reference Guide
.)
Cause 4
SNMP is disabled.
Remedy
Set <SNMP Settings> to ‘On’. (See “Communication Environment Setup,” on
p. 2-6.)
Cause 5
The SNMP community name does not match.
Remedy
Check the correct SNMP community name is used. If the SNMP community
name set for your utility is different from the one set for the machine, the utility
will not detect the machine. (See “Communication Environment Setup,” on
p. 2-6.)