Chapter 8
8-32
2F86
! SP unit cover is open.
Close it and then press OK.
Spectrophotometer cover open/closed
detection sensorwon't respond.
1. Close spectrophotometer cover.
2. Replace cover sensor.
3. Replace the spectrophotometer unit
PCB.
2F87
! Colorimetric readout error.
Please press OK and execute
color measuring again.
When executing color measuring, the
spectrophotometer sensor returned a value
other than predetermined value was
returned.
1. Operate paper feed adjustment.
2. Change the patch size to large.
3. Printer support (In case of printing
failure).
4. Replace spectrophotometer sensor
2F88
! Colorimetric readout error.
Please press OK and execute
color measuring again.
When reading the positioning bar, a value
other than predetermined value was
returned.
1. Operate paper feed adjustment.
2. Printer support (In case of printing
failure).
3. Replace spectrophotometer sensor.
2F89
! Colorimetric readout error.
Please press OK and execute
color measuring again
1) No shifting amount detected from the
positioning bar reading value.
2) Position shifting exceeded the threshold
value.
3) Skew exceeded the threshold value.
1. Operate paper feed adjustment.
2. Printer support (In case of printing
failure).
3. Replace spectrophotometer sensor
2F90
Detected 3V of abnormal power out from
the printhead.
(Latch up current flows at head logic and
temporarily the print head falls into
abnormal state ; it is possible to recover by
power on and off.)
2FA0
!It is recommended to clean
the white calibration board
to prevent it from possible
dirt.
Inform the calibration timing of the
spectrophotometer sensor.
Calibrate the spectrophotometer
sensor.
4001
ERROR E146-4001
Call for service.
ERROR E146-4001
Call For Service
Borderless/flow pre-ejection/mist recovery
count full
Check the parts counter and replace the
target unit or Refresh Service Kit.
Initialize the parts counter for the
target unit after the replacement.
401A
ERROR E602-401A
Call for service.
HDD failure
Failed to read and write to and from the
HDD.
1. Restart in service mode.
2. Remove and install HDD
3. Replace HDD. Switch on service
mode after the replacement.
401B
ERROR E602-401B
Call for service.
Poor HDD connection
The HDD and the HDD controller are not
indefinable.
1. Restart in service mode.
2. Remove and install HDD
3. Replace HDD. Switch on service4.
Replace HDD controller or the main
controller PCB. Restart after the
replacement.
401C
ERROR E198-401C
Call for service.
ERROR E198-401C
Call For Service
Faulty RTC
Any error other than the two errors
mentioned below has been detected while
initializing the RTC at startup.
1. Restart the printer in service mode.
2. Replace the main controller PCB.
401D
ERROR E198-401D
Call for service.
ERROR E198-401D
Call For Service
RTC low battery error
A battery error has been detected while
initializing the RTC at startup.
1. Restart the printer in service mode.
2. Check the RTC battery.
3. Replace the main controller PCB.
401E
ERROR E198-401E
Call for service.
ERROR E198-401E
Call For Service
RTC clock stop
The RTC has been detected idle while
initializing the RTC at startup.
1. Restart the printer in service mode.
2. Replace the main controller PCB.
4027
Hardware error.
03130031-4027
Turn off printer,
wait, then
turn on again.
Power On
Again
Lift Motion
Timeout
Lift shift timeout error
A lift operation has been executed, but no
sensor has been detected or a sensor has
remained detected.
1. Switch off the printer, then back on.
2. The carriage cannot travel to the lift
drive position.
3. The lift drive cam is not engaged.
4. Faulty lift drive sensor
5. Faulty lift drive motor
6. Replace the main controller PCB.
4034
ERROR E196-4034
Call for service.
ERROR E196-4034
Call For Service
Multisensor unit version error
A different version of multisensor is
installed.
This would not occur in an ordinary user
environment.
Replace the multisensor unit.
4037
ERROR E173-4037
Call for service.
ERROR E173-4037
Call For Service
Linear scale error
No signal is available from the carriage
encoder when the printhead is driven.
403E
ERROR E161-403E
Call for service.
ERROR E161-403E
Call For Service
Head abnormal temperature rise (printhead
1 (R), or A model)
Either of the two Di sensors maintained for
each printhead chip (color-specific) has
been detected at 120 degrees C or higher or
-10 degrees C or lower.
403F
ERROR E161-403F
Call for service.
ERROR E161-403F
Call For Service
Head abnormal temperature rise (printhead
2 (L))
Either of the two Di sensors maintained for
each printhead chip (color-specific) has
been detected at 120 degrees C or higher or
-10 degrees C or lower.
Code
(last 4 digits)
Panel display
(Large LCD)
Panel display
(Small LCD)
Explanation/Detection sequence
Remedial Action
Summary of Contents for iPF8400S Series
Page 1: ...Feb 27 2017 Service Manual iPF8000 series iPF8400S ...
Page 2: ......
Page 6: ......
Page 11: ...Chapter 1 PRODUCT DESCRIPTION ...
Page 12: ......
Page 14: ......
Page 63: ...Chapter 2 TECHNICAL REFERENCE ...
Page 64: ......
Page 106: ......
Page 107: ...Chapter 3 INSTALLATION ...
Page 108: ......
Page 110: ......
Page 123: ...Chapter 3 3 13 F 3 22 6 FAN UNIT A ...
Page 125: ...Chapter 3 3 15 ...
Page 126: ......
Page 127: ...Chapter 4 DISASSEMBLY REASSEMBLY ...
Page 128: ......
Page 130: ......
Page 167: ...Chapter 4 4 37 ...
Page 168: ......
Page 169: ...Chapter 5 MAINTENANCE ...
Page 170: ......
Page 172: ......
Page 177: ...Chapter 6 TROUBLESHOOTING ...
Page 178: ......
Page 180: ......
Page 215: ...Chapter 7 SERVICE MODE ...
Page 216: ......
Page 218: ......
Page 272: ...Chapter 7 7 54 ...
Page 273: ...Chapter 8 ERROR CODE ...
Page 274: ......
Page 276: ......
Page 311: ...Feb 27 2017 ...
Page 312: ......