65
c-31) Put the high voltage PCB [1] back to the original position and put the harness [2] inside the host
machine. Be careful not to pinch the harness when closing the controller box [3]. Remove the 2 screws [4] of
the hopper unit (Y)/ (M)/ (C).
c-32) Open the controller box again and temporarily place the high voltage PCB on the controller box.
c-33) Remove the 2 screws [1], 4 bosses [2] and 1 hook [3]. Release the 4 harnesses of the high voltage