SERVICING PROCEDURE:
Factory:
Several design alterations including the removal of the Mylar Sheet [2] from the Registration Guide [1], as
well as structural changes, were implemented in an effort to prevent originals from becoming entangled
between the guides (Figure 2).
In addition, the shape of the Paper Feed Guide (Figure 3) is changed in conjunction with the change of the
Registration Guide.
Field:
In the event the symptom described above occurs, replace both the Registration Guide (FL2-9670-000) and
Paper Feed Guide (FL2-9671-000) with the new type. Be sure to replace both parts at the same time. Please
reference the associated document “Countermeasure Parts Replacement.pdf” for detailed replacement
instructions.
Figure 2
Registration Guide
[A] Old Type
[B] New Type
Figure 3
Paper Feed Guide
[A] Old Type